86 Process Image
WAGO-I/O-SYSTEM 750
750-489 4AI RTD/TC/Strain Gauge Ex i
Manual
Version 1.1.0, valid from FW Version 02
4.7.1
Resistance Measurement 1 (0 Ω
…
250 Ω)
4.7.1.1 Standard Format
Table 95: Setting: Resistance Measurement 1 – Standard Format
Resistance
[
Ω
]
Numeric Value
Status
Byte,
Hex.
Error
LED
Range
Binary
Hex.
Dec.
< 0.0
'1000.0000.0000.0000' 0x8000
-32768
0x50
On
Underflow
0.0
'0000.0000.0000.0000' 0x0000
0
0x00
Off
Nominal range
50
'0001.0011.1000.1000' 0x1388
5000
100
'0010.0111.0001.0000' 0x2710
10000
150
'0011.1010.1001.1000' 0x3A98
15000
200
'0100.1110.0010.0000' 0x4E20
20000
250
'0110.0001.1010.1000' 0x61A8
25000
250.01
'0110.0001.1010.1001' 0x61A9
25001
0x42
On
Overrange
275
'0110.1011.0110.1100' 0x6B6C
27500
≥ 275.01
'0111.1111.1111.1111' 0x7FFF
32767
0x60
On
Overflow
4.7.1.2 S5-FB250 Format
Table 96: Setting: Resistance Measurement 1 – S5-FB250 Format
Resistance
[
Ω
]
Numeric Value
Status
Byte,
Hex.
Error
LED
Range
Binary
XFÜ
1)
Hex.
Dec.
< 0.0
'1000.0000.0000.0 010'
0x8002
-32766
0x50
On
Underflow
0
'0000.0000.0000.0 000'
0x0000
0
0x00
Off
Nominal
range
50
'0000.1111.1010.0 000'
0x0FA0
4000
100
'0001.1111.0100.0 000'
0x1F40
8000
150
'0010.1110.1110.0 000'
0x2EE0
12000
200
'0011.1110.1000.0 000'
0x3E80
16000
250
'0100.1110.0010.0 000'
0x4E20
20000
250.1
'0100.1110.0010.1 001'
0x4E29
20009
0x42
On
Overrange
275
'0101.0101.1111.0 001'
0x55F1
22001
≥ 275.1
'0111.1111.1111.1 010'
0x7FFA
32762
0x60
On
Overflow
1)
Status bits: X= not used, F= error, Ü= overflow