Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
6 Assembly and Commissioning
42
Order number 2333538 | Edition 03/2021
6.5 ASSEMBLY AND INSTALLATION
WARNING
Inclined ground!
Risk of accidents if the device rolls away/falls.
4
Place device on level ground and secure it.
4
If the floor is inclined, position the feet of the trolley towards the gradient.
4
Secure the trolley.
Info
Ensure that the national explosion prevention rules and regulations are observed when
setting up the device.
This pump can be used as part of a spraying system for Airless or AirCoat applications. The
individual components are shown in the accessories, or can be arranged with a spraypack
configurator. The nozzles must be selected according to the spray gun operating manual. In
the case of spraypack orders, the pumps (1) are already pre-mounted on a trolley (6) or on a
frame at the factory.
1. Mount pump (1) on frame, trolley (6) or wall mount.
2. Mount the AirCoat regulator (7) with an AirCoat system.
3. Mount high-pressure filter (3) or filter relief combination and inline filter.
4. Fit suction system (5).
5. Mount return tube (4) or return hose.
6. Connect high-pressure hose and spray gun (2) according to the operating manual for
the spray gun.
5
6
7
4
1
3
2
B_03915
AirCoat system