Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
5 Description
28
Order number 2333538 | Edition 03/2021
Description
Units
Leopard
35-70
Leopard
48-110
Leopard
35-150
Leopard
26-200
Sound pressure level at 0.6 MPa; 6 bar;
87 psi air pressure*
dB(A)
74
78
Sound pressure level at 0.4 MPa; 4 bar;
58 psi air pressure*
dB(A)
71
69
74
Product input (outside thread)
mm
M36×2
Product output (outside thread)
inch
M24×1.5
Weight
kg; lb
26; 57
36; 79
43; 95
Product pH value
pH
3.5 – 9
Product pH value for TC 1.4404 pumps
with acidic hardeners
pH
**
/
Maximum product pressure at pump
inlet
MPa
bar
psi
2
20
290
Product temperature
°C
°F
5 – 80
41 – 176
Ambient temperature - Assembly and
operation
°C
°F
5 – 50
41 – 122
Ambient temperature - Storage
°C
°F
-20 – 60
-4 – 140
Relative humidity
%
10–95 (without condensation)
Allowable inclination for operation
∠
°
± 10
** Check products for compatibility (Chapter Materials of Paint-wetted Parts for Acidic
Hardeners [
22]).
* Measured A-rated emission sound pressure level at distance of 1 m, LpA1m in accordance
with DIN EN 14462: 2015. Reference measurements have been made by Suva (Swiss National
Accident Insurance Fund).
Note: A daily noise exposure level LEX,8h as of 80 dB(A) requires staff to be informed and
hearing protection to be provided.
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4
Provide compressed air free from oil and water.