20
VERSION 02/2019
ORDER NUMBER DOC 2397374
TOPFINISH GM 1030P
6.3
INSTALLATION CONDITIONS
The air temperature at the installation site must be in a range between 5 °C and 40 °C
(41 °F and 104 °F).
The relative air humidity at the installation site must be between 10 and 95% (without
condensation).
6.4
INSTALLATION AND CONNECTION
The Airspray manual gun Topfinish GM 1030P must be supplemented with various
components to make up a spraying system. The system shown in the figure is only one
example of an Airspray spraying system. Your WAGNER distributor would be happy to
assist you in creating a spraying system solution that meets your individual needs.
You must familiarize yourself with the operating manuals and the safety regulations of all
additional system components before starting commissioning.
6.4.1 TYPICAL AIRSPRAY SPRAYING SYSTEM
F
G
B
D
E
H
B_06969
C
A
Designation
Designation
A Airspray spray gun
E Return line
B Air hose, electrically conductive
F Product pump
C Protective hose
G Pressure regulator
D Product hose
H Suction system
6.4.2 VENTILATION OF THE SPRAY BOOTH
Operate the device in a spray booth approved for the working materials.
- or -
Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
Observe national and local regulations for the exhaust air speed.