74
VERSION 01/2021
ORDER NUMBER DOC2422004
TOPFINISH Bell 1S ECH
17 CONNECTION PLANS
17.1 HIGH-VOLTAGE SYSTEM WITH DISCHARGER
H
igh-
voltage cascade
HV distributor
Grounding
Schnier
smart E-310Dp
-A1
+HS/2.0
=PLC.BUS+HS/2.4
HV
PE
TOPFINISH RobotBell 1 ECH/TOPFINISH Bell 1S ECH
HVE 03/01
-A2.1
O1
I1
O2
O3
PE
HKA 03/02-vio
-W11
GNYE
6 mm²
+
1x0,75
1 m
HKA 02/01-rt
-W11
B_07458
17.2 HIGH-VOLTAGE SYSTEM WITH GROUND SWITCH
H
igh-
voltage cascade
Ground switch
H
igh v
oltage
Length at least 3m
Schnier
smart E-310p
-A1
HV
PE
TOPFINISH RobotBell 1 ECH/TOPFINISH Bell 1S ECH
-A2
2
4
1
3
HKA 03/02-vio
-W10
PE
HKA 03/02-vio
-W12
HKA 03/02-vio
-W10
GNYE
6 mm²
+
+
PE
B_07459