40
Super Finish 23 CR
EN
10.6
REMEDY IN CASE OF FAULTS
TYPE OF MALFUNCTION WHAT ELSE?
POSSIBLE CAUSE
MEASURES FOR ELIMINATING THE MALFUNCTION
Unit does not start
Indicating lamp does
not illuminate
No voltage applied
Check voltage supply
Indicating lamp illumi-
nates
Unit fuse has triggered
Let the motor cool down
Unit does not suck in
Air bubbles do not exit
at the return hose
Inlet valve clogged
Press the inlet valve button until the stop is
reached several times by hand
Inlet/outlet valve soiled
/ foreign bodies (e.g.
threads) drawn in / worn
Remove the valves and clean then (-> refer to
Section Pkt.10.2/10.3) / replace worn parts
Pressure control valve
turned down completely
Turn the pressure control valve to the right un-
til the stop is reached
Air bubbles exit from
the return hose
Unit is sucking in outside
air
Check: Inlet valve button leaky? -> Replace
wiper and O-ring (-> refer to Section 10.1)
The red entry is missing in the coating mate-
rial entrance (-> see 4.3)
Unit does not gener-
ate pressure
Unit has sucked in
Air in the oil circuit
Bleed the oil circuit in the unit by turning the
pressure control valve completely to the left
(until overturning) and let it run approx. 2 – 3
min. Then turn the pressure control valve to
the right and set the pressure (repeat process
several times, if necessary).
Not enough oil
Check the oil level
Pressure collapses dur-
ing work (this can be
seen on the pressure
gauge)
Suction filter clogged
Check the suction filter. If necessary, clean, re-
place or remove
Paint cannot be worked in
this state. Due to its prop-
erties the paint clogs the
valves (inlet valve) and the
delivery rate is too low.
Dilute the paint
Unit reached pressure,
but the pressure col-
lapses during spraying.
pressure gage still
shows high pressure
Clogged filter do not let
enough paint pass
Check/clean the gun filter
Tip clogged
Clean the tip (-> refer to Section 10.1)
Unit does not generate
the max. pressure pos-
sible. Even though the
discharge tap is closed,
material still emerges
from the return flow
hose.
Discharge tap defective
Please contact Wager Customer Service
No material is fed (in
injection work)
The pressure gauge
indicates pressure
The gun filter has not
been removed and is
blocked
Remove gun filter
(-> refer to Section 4.1)
REPAIRS AT THE UNIT
Содержание SUPER FINISH 23 CR
Страница 95: ...95 Super Finish 23 CR 1 1 a b c 2 a b c d e f 3 a b c d e f g 4 a RU...
Страница 96: ...96 Super Finish 23 CR 2 a EN 1953 2 1 21 2 2 0 1 2 3 2 3 b c d e f g 5 a b RU...
Страница 97: ...97 Super Finish 23 CR 2 8 2 4 2 5 2 6 15 2 7 2 9 25 250 2 10 20 WAGNER 2 11 1 RU...
Страница 99: ...99 Super Finish 23 CR 3 2 WAGNER 20 000 3 2 2 3 2 1 3 3 SuperFinish23PLUS b RU...
Страница 104: ...104 Super Finish 23 CR 6 20 Wagner 5 1 Wagner 6 Wagner 7 8 1 OFF 2 3 4 1 8 21 1 2 ON RU...
Страница 105: ...105 Super Finish 23 CR 3 4 5 Eimer halten 6 7 8 9 10 11 12 13 1 2 14 15 8 2 1 1 2 1 2 2 3 8 1 1 2 1 RU...
Страница 109: ...109 Super Finish 23 CR 10 6 10 2 10 3 10 1 4 3 2 3 Wagner RU...
Страница 110: ...110 Super Finish 23 CR 4 1 RU...
Страница 116: ...116 Super Finish 23 CR 12 Wagner 01 01 1990 Wagner 2002 96 Wagner 01 02 2009 1 Wagner Wagner 2 12 12 12 3 2 RU...
Страница 117: ...117 Super Finish 23 CR 4 Wagner 5 18 88677 RU...
Страница 118: ...118 Super Finish 23 CR RU...
Страница 119: ...119 Super Finish 23 CR RU...