42
Plast Coat 830
GB
6.8.2
RINSe tHe MORtAR HOSe
(PNeuMAtIC SPRAy LANCe)
• Switch off compressor.
Do not bend the mortar hose!
Protect it against damage, for exam-
ple against being driven over as well as
against sharp objects and edges.
• Hold spray lance over an empty bucket.
•
Set selector switch to “F”.
• Open material tap (Fig. 18, 1) on spray lance. (Material tap at
90° to spray lance)
•
If cellulose paste comes out of the tip, close the material tap
(fig. 18, 1) (material tap points forwards).
• Set selector switch to “A”.
• Fill coating material into the receptacle.
With mineral coating materials only fill the re
-
ceptacle to half full.
• Position the spray lance over the bucket again.
•
Set selector switch to “F”.
• Open material tap (Fig. 18, 1) on spray lance.
• As soon as coating material exits from spray lance, close ma
-
terial tap (Fig. 18, 1).
• Set selector switch to “A”.
• Switch on compressor.
The mortar spraying machine is now full and ready.
6.8.3
FILLING tHe CONtAINeR WItH A BAG SuPPORt
(ACCeSSORy)
•
Place bag on support such that the face end is facing the
opening.
•
Cut sack open.
•
Allow the coating material to flow into the receptacle.
Danger of crushing
Do not place hands under the roller.
•
Place pressing roller on rear end of bag and roll forwards
several times over the bag.
With mineral coating materials only fill the re
-
ceptacle to half full.
•
Strip remaining coating material from sack opening with a
spatula.
commIssIonIng
6.9
BeGINNING OF tHe SPRAyING PROCeSS
•
Open the air flow regulator (fig. 18, 3) and the material tap
(18, 1) at the spray lance.
• Adjust the flow of material with the delivery volume con
-
troller (fig. 18, 2) on the control unit and set the air quantity
by adjusting the air flow regulator (fig. 18.3) to attain the
desired spray pattern.
Important: Do not let the mortar spraying
machine run dry. Switch the device off im-
mediately if no more material comes out of
the tip or if the spray line becomes irregu-
lar. Possible reasons for the problem and
how to correct it can be found in the chap-
ter called „eliminating faults“.
Increased material tap wear. Do not use the
material tap to set the material volume.
the delivery volume controller should be
used for this purpose.
6.10
eND OF tHe SPRAyING PROCeSS
• Close the material tap (
Fig. 18, 1).
• Close the air flow regulator (fig. 18.3).
Always close material tap at end of the
spray process.
1
3
2
POWER
ERROR
SPEED
R
A
F
Содержание Plast Coat 830
Страница 111: ...111 Plast Coat 830 NL...