35
Plast Coat 830
GB
4.1
OPeRAtING eLeMeNtS AND DISPLAyS ON
DeVICe
1
Delivery volume controller
0-10
2 Selector switch for operating mode
3 Indicator light (Error)
4 Operating light (Power)
5 EMERGENCY STOP switch
The delivery volume controller (
Fig. 3, 1) is used to regulate
the convey capacity from 0-10 smoothly.
The remote control (available separately, art.
no. 2308 417) can be used to conveniently
control the pump‘s delivery volume from the
spray lance.
The selector switch (Fig. 3, 2) offers the following modes:
A
R
F
“A” position = automatic
Basic setting for control with an automatic
spray lance, pneumatic spray lance or re
-
mote control
A
R
F
“F” position = manual activation
Switches on the mortar spraying machine.
This setting is required for:
• disassembling the pump unit
When using the pneumatic lance, this set-
ting is also needed for:
• pre-rinsing the mortar hose to improve
the material‘s ability to slide
• cleaning
A
R
F
“R” position = reverse gear (must be held in
this position).
This setting is required for:
• relieving pressure on the mortar hose
• assembling the pump unit
overvIew
Detailed explanation of selector switch use:
If the selector switch is in the “A” position, the PC830 can be
switched on and off with the material shut-off on the auto-
matic or pneumatic spray lance.
If there is no spray lance fitted (e.g.: assembly/disassembly the
pump unit ), the machine is switched on using the “F” switch
position and off using the “A” position.
Since the air supply through the compressor needs to be
switched off to clean the mortar hose, the pneumatic lance
is not controlled using the material shut-off. In this case, the
machine must therefore also be switched on using the “F” po-
sition.
Important: control via the selector switch and
material shut-off are treated equally.
The machine can be switched from the “A” po-
sition (control using material shut-off) to “F” at
any time.
We would therefore recommend that only one
person operate the machine.
The operating light (green, Fig. 3, 4) indicates that the machine
is energised and ready.
When the mains plug is connected the PC 830 carries out a
function check. While this is going on the indicator light (red,
fig. 3.3) flashes. If everything is in working order, the flashing
stops after about 30 seconds. If the indicator light lights up
during operation, this indicates that there is a malfunction. For
detailed information about this kind of fault, refer to the „Rec-
tification of faults“ section on page 46.
If the selector switch is in the “F” position when
the mains plug is plugged in, the machine will not
switch on.
Briefly move selector switch to “A” and then back
to “F” to switch on the machine.
eMeRGeNCy StOP switch
When the EMERGENCY STOP switch is pressed, the PC 830 is
switched off immediately.
Turn the EMERGENCY STOP switch in order to release it again.
The machine remains switched off after release. To switch it on
again, the selector switch must be briefly set to “A” and then
to “F”.
4.2
DRIVe
When an overload occurs, the mortar spraying machine
switches off automatically (red indicator light lights up).
Move selector switch (Fig. 3, 2) to “A” and disconnect mains
plug. Set delivery volume controller (Fig. 3, 1) to „0“.
Wait around 5 minutes, then plug the mortar spraying machine
back in and switch on. Set the delivery volume required.
The drive unit heats up during operation. This
is normal and not a sign of malfunction.
POWER
ERROR
SPEED
R
A
F
2
1
4
3
5
Содержание Plast Coat 830