30
PEM-X1
P_01669
OPERATING MANUAL
VERSION 09/2012
ORDER NUMBER DOC 2326020
7.5
ADJUSTMENT OF POWDER QUANTITY
LED display green
Reduce powder quantity
Increase powder quantity
LED display
Control mode
Flashing
Normal operation of gun
Constant blinking
Activated recipe has been changed using the "+" or
"-" button.
By selecting another recipe the modifi ed values of
the powder quantity are not taken over, however, the
current values of the other recipe are taken over and
the blinking changes to fl ashing.
By saving these settings the current values of the
powder feed are taken over in the current recipe. The
blinking changes back to fl ashing.
By activating the "double click" function the blinking
is switched off as well, the preset program values are
then active again.
Permanent lighting
Trigger has been actuated with "double click", i.e. the
"double click" program is activated
Note:
This function can only be activated in combination with the EPG-Sprint X control unit.
By pressing the buttons „+/-“ the preset program values of the feed air (powder quantity)
can be changed in the desired direction.
In this case the total air remains unchanged, the feed and dosage air is readjust accordingly.
Содержание PEM-X1
Страница 2: ......
Страница 65: ...65 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020 14 4 EC TYPE EXAMINATION CERTIFICATE...
Страница 66: ...66 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 67: ...67 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 68: ...68 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020 14 5 FM APPROVAL in submission...
Страница 69: ...69 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 71: ......