26
PEM-X1
P_01120
1
2
3
6
7
5
4
OPERATING MANUAL
VERSION 09/2012
ORDER NUMBER DOC 2326020
6.6.1
GROUNDING THE POWDER COATING SYSTEM
The footwear worn by the operators must comply with the requirements of
EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ
(megaohms).
The protective clothing, including gloves, must comply with the requirements of
EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ
(megaohms).
Sparks between conveyor, conveyor hooks (hangers) and work piece can occur
if electric contact points between conveyor, conveyor hooks (hangers) and work
piece are not suffi
ciently cleaned and therefore the work pieces are not suffi
ciently
grounded!
These sparks can cause severe radio frequency interference (electro-magnetic
compatibility = EMC).
1
Only use mains cables with grounding strand!
2
Connect grounding cable with booth and system ground!
3
Connect grounding cable to an uncoated metal part of the booth!
4
All paint must be removed from hook and other hanger parts!
5
Wear electrostatically conductive gloves!
6
Wear electrostatically conductive footwear!
7
The fl oor must be electrostatically conductive!
Содержание PEM-X1
Страница 2: ......
Страница 65: ...65 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020 14 4 EC TYPE EXAMINATION CERTIFICATE...
Страница 66: ...66 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 67: ...67 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 68: ...68 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020 14 5 FM APPROVAL in submission...
Страница 69: ...69 PEM X1 OPERATING MANUAL VERSION 09 2012 ORDER NUMBER DOC 2326020...
Страница 71: ......