23
FinishControl 3500
GB
CORRECTION OF MALFUNCTIONS
Warning
If the supply
c
ord of this applian
c
e is damaged, it must only
be repla
c
ed by a repair shop appointed by the manufa
c
turer,
be
c
ause spe
c
ial purpose tools are required.
The wires in this mains lead are
c
oloured in a
cc
ordan
c
e with
the following
c
ode:
green/yellow
=
earth
blue = neutral brown = live
As the
c
olours of the wires in the mains lead of this applian
c
e
may not
c
orrespond with the
c
oloured markings identifiying
the terminals in your plug, pro
c
eed as follows:
•
The wire whi
c
h is
c
oloured green and yellow must be
c
onne
c
ted to the terminal in the plug whi
c
h is marked with
the letter E or by the earth symbol or
c
oloured green or
green and yellow.
•
The wire whi
c
h is
c
oloured blue must be
c
onne
c
ted to
the terminal whi
c
h is marked with the letter N or
c
oloured
bla
c
k.
•
The wire whi
c
h is
c
oloured brown must be
c
onne
c
ted to
the terminal whi
c
h is marked with the letter L or
c
oloured
brown.
•
Should the moulded plug have to be repla
c
ed, never re-use
the defe
c
tive plug or attempt to plug it into a different 13 A
so
c
ket. This
c
ould result in an ele
c
tri
c
sho
c
k.
14
CORRECTION OF MALFUNCTIONS
MALFUNCTION
CAUSE
REMEDY
The unit will not start
•
No mains voltage
•
Che
c
k
No
c
oating material emerges
from the nozzle
•
Nozzle
c
logged
•
Material volume setting too low
•
Paint
c
ontainer seal damaged
•
No pressure build-up in
c
ontainer
•
Container empty
•
Ventilation hose loose/damaged
•
Feed tube loose
•
Feed tube / feed tube filter
c
logged
•
Air vent on feed tube blo
c
ked
•
Diaphragm stu
c
k
•
The diaphragm is positioned the
wrong way round.
•
Clean
•
In
c
rease volume
•
Repla
c
e
•
Tighten
c
ontainer
•
Refill
•
Insert or repla
c
e
•
Insert
•
Clean or use another filter
•
Clean
•
Remove and
c
lean (see se
c
tion 13.2)
•
Position the diaphragm
c
orre
c
tly (see se
c
tion
13.2)
Coating material drips from the
nozzle
•
Air
c
ap, nozzle or needle soiled
•
Spray atta
c
hment in
c
orre
c
tly
assembled
•
Nozzle loose
•
Nozzle seal is missing or worn
•
Nozzle worn
•
Needle worn
•
Clean
•
Assemble
c
orre
c
tly (see se
c
tion 12.1)
•
Tighten Union nut
•
Insert an inta
c
t nozzle seal
•
Change
•
Use new spray atta
c
hment
•
Should it be ne
c
essary to ex
c
hange the fuse in the plug only
use fuses approved by ASTA in a
cc
ordan
c
e with BS 1362.
Only 13 Amp fuses may be used.
•
To ensure that the fuse and fuse
c
arrier are
c
orre
c
tly
mounted please observe the provided markings or
c
olour
c
oding in the plug.
•
After
c
hanging the fuse, always make sure that the fuse
c
arrier is
c
orre
c
tly inserted. With out the fuse
c
arrier, it is not
permissible to use the plug.
•
The
c
orre
c
t fuses and fuse
c
arriers are available from your
lo
c
al ele
c
tri
c
al supplies sto
c
kist.
Содержание FINISH CONTROL 3500
Страница 3: ...FinishControl 3500 e 1 d 1 f 1 g A B 3 20 cm j 9 1 2 k i 1 2 1 h 7 1 7 2 7 3 7 4 8 8 9 12...
Страница 5: ...FinishControl 3500 3 2 1 14 1 2 3 5 6 7 8 9 10 11 12 13 15 4 13 2 11 11 15 3 2 1 3 4 5 6 7 8 15 2 9...
Страница 130: ...124 FinishControl 3500...
Страница 131: ...125 FinishControl 3500...