Operating manual Piston Pump EvoMotion 5-60
7 Operation
Order number 2333563 | Edition 10/2020
33
7 OPERATION
7.1 TRAINING THE OPERATING PERSONNEL
– The operating personnel must be qualified to operate the entire system.
– The operating staff must be familiar with the potential risks associated with improper
behavior as well as the necessary protective devices and measures.
– Before work commences, the operating personnel must receive appropriate system
training.
7.2 EMERGENCY STOP
In the case of unforeseen occurrences immediately:
1. Close ball valve (2).
2. Pull safety valve (5). Relieve the product-conveying parts of pressure via the return
valve (8), or via the spray gun or an outlet valve in the product outlet (4).
B_04092
2
5
4
8
7.3 TASKS
Ensure that:
commissioning is carried out in accordance with Chapter Commissioning [
31].
1. Carry out a visual inspection: Personal protective equipment, grounding and all devices
ready for use.
2. Secure spray gun (3) and insert nozzle into the spray gun.
3. Close return valve (8).
4. Slowly open the ball valve (2).
5. Set the required operating pressure on the pressure regulator (1).
6. Optimize spray pattern according to specifications in the spray gun operating manual.
7. Start work process.