60
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
6.4
INSPECTIONS IN ACCORDANCE WITH DIN EN 50348
6.4.1
OVERVIEW OF INSPECTIONS
Paragraph
Type of inspection
Requirements
1
Inspection for safe operational condi-
tion
Safe operational condition of the complete system
2
Inspection of technical ventilation
Effectiveness of technical ventilation
3
Switch off of high voltage in voltage
controlled and constant voltage operat-
ing mode
Safe switch off of high voltage
4
Switch off of high voltage in constant
current operating mode
Safe switch off of high voltage
5
Protection against excessively high
discharge energy
Safe discharge of all high voltage conducting parts
after switching off high voltage
6
Protection against direct contact
Safe switch off of high voltage for access to live
system parts
7
Earthing inspection
Earthing of the complete system
8
Locking device/Entry protection
Safe switch off of high voltage for access to live
system parts
9
Inspection of conductive parts in the
coating material system
Inspection of conductive parts of the coating mate-
rial supply for earthing and potential
10
Minimum distance in air
Minimum distance between earthed and high volt-
age conducting parts
If the system is used for electrostatic coating with non-fl ammable liquid coating materials
(water-based paints), the inspection in accordance with DIN EN 50348: 2010-05 as per table
3 must be performed.
Further inspections must be performed in accordance with EN 12215.