![WAGNER Evobell 3500 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/wagner/evobell-3500/evobell-3500_translation-of-the-original-operating-manual_3134313059.webp)
59
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
6.3.2
INSPECTION INTERVALS IN ACCORDANCE WITH TABLE 4 OF DIN EN 50176: 2010-04
Paragraph
Inspection point
Inspection interval
category 2
Inspection interval
category 3
1
Safe operational condition of the complete
system
12 months
12 months
2
Effectiveness of technical ventilation
Continuously
Continuously
3
Overcurrent cut-out
Whenever the system
is switched on
Whenever the system
is switched on
4
Undervoltage cut-out
Whenever the system
is switched on
Whenever the system
is switched on
5
Discharge energy
Weekly
Weekly
6
Ignition protection for fl ammable cleaning
agents
Before all cleaning
tasks
Weekly
7
Protection against contact
Weekly
Weekly
8
Earthing measures
Weekly
Weekly
9
Locking device/Entry protection
Weekly
Weekly
10
Fire extinguishing equipment
6 months
6 months
11
Conductive parts of the coating material
system
Weekly
Weekly
12
Minimum distance in air
Weekly
Weekly