30
Evobell 3500
OPERATING MANUAL
EDITION 05/2010
PART NO. DOC387841
5
START-UP AND OPERATION
5.1.1
TYPICAL ELECTROSTATIC SPRAYING SYSTEM
5.1
PUT THE EQUIPMENT IN PLACE AND CONNECT
Note:
The high rotation atomizer Evobell 3500 must be used a part of an electrostatic spraying
system. The spraying system shown in the fi gure is only one example of an electrostatic
Aircoat spraying system.
It is not an actual system design. Contact your Wagner distributor for assistance in design-
ing a system to meet your needs.
The high-rotation atomizing plant may only be commissioned by trained skilled specialist
personnel. Ensure that the operating personnel has familiarized itself with the additional
operating instructions and safety specifi cations of all the system components.
After completion of the installation, the capacity of the complete system must be meas-
ured and documented accordingly.
SIHI_0075_GB
WARNING
Incorrect installation/operation!
Risk of injury and damage to equipment
The entire plant is to be evaluated in accordance with Directive
1999/92/EC (ATEX 137) before the initial start-up!
When putting into operation and for all work, read and follow
the operating instructions and safety regulations for the
additionally required system components.
SIHI_0076_GB
CAUTION
Impurities in the spraying system!
Dirt and humidity in the hose system can cause damage to the atomizer, in particular
also to the drive turbine
Hose length between filter bearing air and atomizer
≤
10 m; 11 yd.
Hose length between filter (drive, brake, atomizer air and atomizer
≤
30 m; 33 yd.
High voltage generator (Typ, Model)
Measured capacity