![WAGNER AirCoat GM 4600AC-H Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/wagner/aircoat-gm-4600ac-h/aircoat-gm-4600ac-h_translation-of-the-original-operating-manual_4516834027.webp)
27
GM 4600AC
B_02677
B
A
64
30
67
66
65
B_02679
OPERATING MANUAL
EDITION 05/2011
Part No. DOC394861
6.3
CHANGING OR CLEANING FILTER INSERT
1. Finishing work and cleaning.
2. Relieve spray gun and unit pressure.
3. Secure gun with trigger safety catch.
4. Place open-ended wrench A on fl ats of fi lter housing (30) and counter hold.
5. Turn nut to the right with open-ended wrench B and unscrew pivot joint (67) with
material hose.
6. Remove the fi lter insert (64), seal (65) and compression spring (66).
7. Thoroughly clean all parts with cleaning agent.
8.
Assembly:
Push cleaned or new fi lter insert (64) with cone upwards into the fi lter housing (30)
9. Insert compression spring (66) into fi lter connection piece (67). Screw on the fi lter
connection piece with seal (65) and material hose by hand and tighten using the two
open-end wrenches A and B.
Counter hold
Description
Key A
Key B
GM 4600AC with fi lter NPS1/4“
SW 15 mm
0.59 inches
SW 17 mm
0.67 inches
Note:
Do not unscrew the fi lter
housing. The nut must only be
unscrewed by WAGNER-Serv-
ice-Agency.