magic watch
Technical data
47
13
Technical data
The sensors may be painted but
not with a multiple-coat paint
as this impairs their functionality.
Versions, technical modifications and delivery options reserved.
Approval
The device has e13 approval.
Detection range:
Up to 1.5 m
Ultrasound frequency:
38.5 kHz
Supply voltage:
10 – 15 Volts
Power consumption:
35 mA (standby mode)
60 mA (signal mode)
Operating temperature:
–20 °C to +70 °C
Piezoelectronic speaker volume:
100 dB (at 10 cm distance)
3