CoolFun CA-35
13
9
Troubleshooting
In the event of malfunction, please check the following:
Fault
Possible cause
Suggested remedy
The cooler does not
The cooler is not
work.
properly connected
to the electricity
supply.
Check if the voltage supply is in full working
order.
Check if all electrical contacts are in full
working order. Check if the voltage
supply corresponds to the value on the
type plate. Check if the thermostat
control is switched on.
Check if several energy sources are
connected at the same time.
The cooler is not
properly connected
to the gas.
Check if the gas supply is in full working
order.
Check if the valve on the gas bottle is
open.
Check if there is still gas in the bottle.
Check if several energy sources are
connected at the same time. Hold the
rotary switch down longer when igniting.
The cooler has not
been set up properly.
Check if the device is horizontal. Check
if the ventilation of the device is
sufficient.
The cooler has not
been filled properly.
Check if warm food has been put into the
device.
Check if the cooling space has been
overfilled or packed too densely.
The refrigerant circuit This can only be repaired by an is defective. authorised customer
services unit.
The cooler does not
start up after a long
period of inactivity.
–
Disconnect the device from the energy
supply and turn the cooler upside down
and wait around five minutes. Turn the
cooler the right way up again and switch
it on again.
10
Technical data
Product Code: CA-35-12240PB37
Capacity:
35 L
Содержание CoolFun CA-35