EN
Technical data
ASC5500G RPA
134
12
Technical data
The display shows
„00002“
The readings are excessively
high.
Keep possible electrical
sources of interference, such
as mobile phones or welding
equipment, away from the
device.
The display shows
„00003“
Calibration with the ambient
air failed.
Ensure the device is ade-
quately ventilated.
Leave any leaking refriger-
ant to drain off.
The display shows
„00004“
The device is operating out-
side the recommended tem-
perature range.
Only use the device in tem-
perature-controlled rooms
(10 °C – 45 °C).
Ensure sufficient ventilation.
The display shows
„00005“
The refrigerant sample has a
very high content of air or the
amount of refrigerant was too
low for testing.
Make sure that there is
enough refrigerant pressure.
Make sure that all the hoses
are connected, not kinked
and free of oil.
AirConServiceCenter
ASC5500G RPA
Item number:
9103301882
Dimensions (width x height x depth)
560 mm x 1300 mm x 650 mm
Weight:
100 kg
Power supply:
220 V/240 V–50 Hz/60 Hz
Refrigerant extraction rate:
30 kg / hr
Vacuum pump output:
5 cars / hr
Hermetic compressor output:
0.32 kW
Drier filter output:
150 kg
Vacuum pump oil service life:
60 h
Filling cylinder accumulator capacity:
16 kg
Noise emission:
55.5 dB (A)
Accuracy of the electronic scale for refrigerant:
± 10 g
Accuracy of the electronic scale for old/new oil:
± 1 g
Accuracy of the electronic scale for UV additive:
± 1 g
Operating temperature range:
+ 5 °C to + 50 °C
Problem
Cause
Remedy