EN
127
ASC5500G RPA
Service tasks
9.11
Changing the drained oil receptacle
I
The drained oil receptacle (
22
) is also leak-proof when there is a vacuum
or overpressure. A safety valve guarantees safe operation.
The drained oil receptacle must be changed every 6 months.
1. Open the cover flap (
23
) on the left side and remove the drained oil
receptacle (
22
) from the snap lock:
2. Release the bracket (
M
) and remove the cover (
N
).
NOTE
Replace the drained oil receptacle and the O-ring in the lid every
6 months.
If the drained oil receptacle has been damaged, replace it
immediately.
23
22
M
N