EN
Operation
ASC5500G RPA
110
8.7
Flushing the air conditioning system
I
1. Start by fitting the connections of the AirConServiceCenter to the
vehicle air conditioning system, and opening them.
2. In the basic menu, use the cursor keys
or
to select
“Free selection”
:
3. Press
ENTER
to confirm.
4. If necessary, use the keypad (
8
) to enter the data and press
ENTER
to confirm.
If no data is to be entered, press
ENTER
to switch to the next pro-
gram step.
5. Select
“Rec/Recycling phase”
(the setting flashes) and press
ENTER
to confirm.
6. For the
“Pressure increase Test time”
, enter
1
minute and press
ENTER
to confirm.
7. Deselect
“Vacuum phase”
using
No
(the setting flashes) and press
ENTER
to confirm.
8. Deselect
“Filling phase”
using
No
(the setting flashes) and press
ENTER
to confirm.
9. Select
“Process start”
by pressing
ENTER
.
10. After the extraction process is complete, disconnect the station from
the vehicle.
NOTE
The
“Flushing”
menu is used to flush the vehicle air conditioning
system with fresh refrigerant. Flushing is especially suitable for
replacing old compressor oil or removing most metallic residue from the
system.
Before flushing, the refrigerant must first be extracted from the vehicle
air conditioning system. Afterwards, the system components which
cannot be flushed must be disconnected from the refrigerant circuit (for
example, the compressor or filter). After that, the components to be
flushed are connected to the service ports of the AirConServiceCenter
using special adapters to form a flushing circuit.
Short selection
Free selection
Other selections
ENTER-OK