Operation
PS2 800 / PSA2 800
4
Operation
4.1
Before Starting
1. Make sure once again that the product is of the correct voltage and frequency
rating.
NOTICE
:
Using the product at other than rated voltage and frequency will not only
lower its performance but may damage the product.
Note:
Confirm the rated voltage and frequency on the model nameplate.
2. Confirm the wiring, supply voltage, circuit breaker capacity, and motor insulation
resistance.
Reference insulation resistance = 20 M
Ω
or greater.
Note:
The reference insulation resistance (20 M
Ω
or greater) is the value when the
pump is new or has been repaired. For the reference value after installation see
“Periodic Maintenance Table.”
3. The setting on the circuit breaker or other overload protector should be made in
accord with the rated current of the pump.
Note:
See “Operating Specifications” for the rated current of the pump.
4. When powering the pump with a generator, be certain the generator is sized to
supply the required power for the pump and any other equipment powered by
the generator.