![Wacker Neuson PS2A 800 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/wacker-neuson/ps2a-800/ps2a-800_operators-manual_3192609019.webp)
wc_tx001644gb_FM10.fm
19
PS2 800 / PSA2 800
Installation
3.9
Cable Assembly
If a cable with cut insulation or other damage is submerged in water, there is a
danger of damage to the pump, electrical leakage, electrical shock, or fire.
Be careful not to let the cable assembly be cut or become twisted. This may result
in damage to the pump, electrical leakage, electrical shock, or fire.
If it is necessary to submerge the connection wires of the cable assembly in water,
first seal the wires completely in a molded protective sleeve, to prevent electrical
leakage, electrical shock, or fire.
Do not allow the cable assembly wires or power supply plug to become wet.
Make sure the cable does not become excessively bent or twisted, and does not
rub against a structure in a way that might damage it.
If used in a deep-well installation, the cable assembly should be secured every 6 m
(20 ft).
CAUTION
Fire, electrical leakage, or electrical shock hazard.
►
If it is necessary to extend the cable assembly, use a core size equal to or larger
than the original. This is necessary not only to avoid a performance drop, but to
prevent cable overheating.