wc_tx003099gb.fm
46
Maintenance
LTN 6L-V
Continued from the previous page.
4. Open the radiator drain
(b)
and let the coolant drain into the container.
5. Close the radiator drain.
6. Remove the engine block coolant plug and let the remaining coolant drain into
the container.
7. Replace the copper seal and reinstall the plug. Tighten the plug to 16.2 ft.lbs.
(22 Nm).
8. Fill the radiator to approximately 19 mm (3/4 in.) below the bottom of the filler
neck. Add more coolant if necessary to maintain this level.
NOTICE:
Do not overfill the radiator. The machine will be damaged.
9. Inspect the radiator filler cap and seal, hoses, clamps, and plugs for damage.
Replace any damaged parts.
10.Clean and reinstall the radiator filler cap.
Important
Use a long-life ethylene glycol coolant in this engine. Refer to the engine owner’s
manual for more information.
wc_gr009465
b
WARNING
Burn hazard. Coolant can contain alkali.
f
Avoid contact with skin and eyes.