wc_tx003097gb.fm
40
Operation
LTN 6L-V
4.17
Receptacle - 50 Hz
Description
This machine is equipped with a convenience receptacle
(d)
for running
accessories and tools from the generator. A circuit breaker
(c)
protects the
receptacle. Power to the receptacle is available any time the engine is running and
the circuit breaker is on.
NOTICES
Obey the instructions below to avoid damaging the machine, accessories, or tools.
Do not use frayed or damaged cords or plugs with the convenience receptacle.
The maximum wattage (lights on) drawn from the receptacles shall not exceed:
convenience receptacle-840W
230V receptacle-1680W
Use only tough rubber-sheathed flexible cable or equivalent. (per 1EC245-4).
When using extension cords or mobile distribution networks, the total length of
cords with a cross-sectional area of 1.5 mm
2
(0.002 in
2
) should not exceed 60
m (197 ft). For cords with a cross-sectional area of 2.5 mm
2
(0.004 in
2
), the total
length should not exceed 100 m (328 ft).
This machine generates increased voltage while the lights are reaching full
brightness. To avoid damaging sensitive electronic equipment, do not connect
any such devices to the convenience outlet until the machine and lights have
been operating for at least ten minutes.
wc_gr009361
230VAC
c
d