![Wacker Neuson G 240 Скачать руководство пользователя страница 159](http://html2.mh-extra.com/html/wacker-neuson/g-240/g-240_operators-manual_3125757159.webp)
wc_tx003871gb_FM10.fm
159
Machines with Aftertreatment Exhaust System
15.4
Monitoring and Control of the DEF Level
The Diesel Exhaust Fluid (DEF) level is monitored by the genset controller. In
normal operation, the DEF level (in percentage of the DEF tank capacity) is
displayed on the left side of the LCD screen. When the DEF tank begins to empty,
the genset controller displays messages alerting the operator of the condition of
the DEF supply. See table below.
Refilling the DEF tank before the DEF level reaches 2.5% avoids DEF-level-
related engine shutdowns.
DEF INDUCEMENT
wc_gr012296
DEF Level
Controller Message
Controller / Machine Response
≥
10%
No message
Normal screen / normal operation
2.5–10%
DEF WARNING
■
Normal operation.
■
LED flashes.
0–2.5%
DEF INDUCEMENT
■
Main circuit breaker trips.
■
Machine runs for 10 minutes, then shuts down.
■
During shutdown the LED is on solid and the LCD screen
shows LOW DEF SHUTDOWN.
The machine may be restarted without adding any DEF, but
will only run for 10 minutes before the genset controller
shuts down the machine. Only the convenience receptacles
are available.
0%
DEF PRESVR INDUCMT
Same as above plus the engine’s SEVERE INDUCMT timer
starts.
30 minutes
after 0%
DEF SEVERE INDUCMT
■
After 30 minutes of run time with 0% DEF, the engine
shuts itself down. This is the first of four shutdowns
allowed by the engine.
Note: The genset controller’s 10-minute run time limitation
is still active within the 30-minute engine run time limit.
Thus, up to three restarts by the genset controller are
possible within the 30-minute engine-controlled run time.
■
The engine will allow four such shutdowns to occur. On the
fourth shutdown, the engine controller will lock out the
engine. The engine can only be unlocked by a Cummins
service technician.
Содержание G 240
Страница 1: ...5000186930 09 0215 5 0 0 0 1 8 6 9 3 0 Operator s Manual Mobile Generator G 230 G 240 EN...
Страница 6: ...Foreword 6 wc_tx003565gb_FM10 fm Notes...
Страница 25: ...wc_tx003568gb_FM10 fm 25 Mobile Generator Label Locations wc_gr009229 UU G H J R GG V V WW FF R A KK H...
Страница 178: ...wc_tx003849gb_FM10 fm 178 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770051...
Страница 179: ...wc_tx003849gb_FM10 fm 179 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770052...
Страница 180: ...wc_tx003849gb_FM10 fm 180 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770048...
Страница 184: ...wc_tx003663gb_FM10 fm 184 Engine Maintenance T4i Cummins QSB6 7 770016...
Страница 211: ...wc_tx003111gb_FM10 fm 211 User s Information for Transport Canada Fuel Tank...
Страница 212: ...wc_tx003111gb_FM10 fm 212 User s Information for Transport Canada Fuel Tank...
Страница 252: ......
Страница 253: ......