wc_tx003610gb_FM10.fm
126
Mobile Generator
Using Remote Start Capabilities
12.3
Preparing for Automatic/Remote Start-Up (Basler)
Background
When the engine start switch is in the REMOTE START position, the generator can
be started remotely through a automatic transfer switch or other type of remote
start switch.
Procedure
Before operating the machine in the remote start mode, do the following:
1. Perform a manual start to verify that the LCD panel is operating correctly. Refer
to topics
Before Starting
and
Starting and Running the Machine
.
a. Check the fuel level and add fuel as needed.
b. Check the battery voltage. Charge the battery if needed.
2. Check the operation of the remote
start circuit:
a. Attach a short jumper wire
(a)
(minimum 16-gauge insulated)
between the two terminals on the
remote run terminal block. The
jumper wire completes the circuit
which initializes the genset
controller start sequence.
b. Set the engine start switch to the
REMOTE START position.
c. Wait for the engine to crank, start,
and run.
d. Move the engine start switch to OFF to stop the engine.
e. Remove the jumper wire from the remote run terminals.
3. Set the voltage selector switch to the correct voltage position.
4. Set the engine start switch to the REMOTE START position.
5. Set the main line circuit breaker to ON.
6. Secure the generator by closing and locking all doors.
The generator is now ready for remote starting.
Maintaining
battery charge
If the generator is to be used as a stand-by power supply, provisions must be made
to maintain the charge of the battery. This can be done either by attaching a battery
charger to the battery or by starting and running the engine periodically.
CAUTION
Possibility of unexpected machine startup. If the contacts on a remote switch
connected to the generator are closed, the machine could start unexpectedly when
the engine start switch is set to the REMOTE START position.
►
Be prepared for engine startup anytime the engine start switch is in the
REMOTE START position.
►
Before placing the engine start switch in the REMOTE START position, verify
that the contacts on any remote/transfer switch connected to the generator are
OFF (OPEN).
20A
20A
50A
50A
0 0 5 6 3 2
AUS
AUS
APAGADO
APAGADO
ARRET
ARRET
OFF
OFF
REMOTE START
REMOTE START
FERNSTART
FERNSTART
ARRANQUE REMOTO
ARRANQUE REMOTO
DEMARRAGE A
DEMARRAGE A
DISTANCE
DISTANCE
START / LAUFEN
START / LAUFEN
ARRANQUE / MARCHA
ARRANQUE / MARCHA
DEMARRER / MARCHE
DEMARRER / MARCHE
START / RUN
START / RUN
a
wc_gr010206
Содержание G 240
Страница 1: ...5000186930 09 0215 5 0 0 0 1 8 6 9 3 0 Operator s Manual Mobile Generator G 230 G 240 EN...
Страница 6: ...Foreword 6 wc_tx003565gb_FM10 fm Notes...
Страница 25: ...wc_tx003568gb_FM10 fm 25 Mobile Generator Label Locations wc_gr009229 UU G H J R GG V V WW FF R A KK H...
Страница 178: ...wc_tx003849gb_FM10 fm 178 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770051...
Страница 179: ...wc_tx003849gb_FM10 fm 179 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770052...
Страница 180: ...wc_tx003849gb_FM10 fm 180 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770048...
Страница 184: ...wc_tx003663gb_FM10 fm 184 Engine Maintenance T4i Cummins QSB6 7 770016...
Страница 211: ...wc_tx003111gb_FM10 fm 211 User s Information for Transport Canada Fuel Tank...
Страница 212: ...wc_tx003111gb_FM10 fm 212 User s Information for Transport Canada Fuel Tank...
Страница 252: ......
Страница 253: ......