Malfunctions
Troubleshooting 10.1
27
[en] | 09/2020 | 5100056242 | FUH | Operator’s manual
10.1.1
Explanation of the Service control light
Malfunction
Cause
Remedy
Not color coded.
Only needed for the
Wacker Neuson contact.
None.
None.
10.1.2
Explanation of control lights for machines with several intermediate decks
For machines with several intermediate decks, different states per ma-
chine can be seen for each intermediate deck. Explanation using an ex-
ample:
Malfunction
Cause
Remedy
Intermediate deck 2:
is not working. Overtem-
perature control light
lights up red.
Intermediate deck 2 has
shut down due to high
temperature (> 85°C).
1) Allow intermediate deck 2 to
cool while the fan is running.
The machine is switched on.
2) Perform reset: Switch the ma-
chine off and on again.
3) Check that both fans are run-
ning and that the ventilation
slots are free. Reduce the cur-
rent consumption of the con-
nected machine.
Intermediate deck 1:
OK.
None.
1) Disconnect connected ma-
chine from intermediate deck
2.
2) Change the connected ma-
chine from intermediate deck
2 to intermediate deck 1 and
continue working.