46
Technical data
EHB 11
12.4
Notes regarding class rating
Class rating
The class rating according to DIN EN 61140 specifies the safety measures for
electrical equipment to avoid electrocution. There are four class ratings:
Class rating
Meaning
0
No special protection apart from the basic insulation.
No grounded conductor.
Plug connection without grounded conductor contact.
I
Connection of all conductive housing components to the
grounded conductor.
Plug connection with grounded conductor contact.
II
Reinforced or double insulation (protective insulation).
No connection to the grounded conductor.
Plug connection without grounded conductor contact.
III
Equipment is operated on protective low voltage
(< 50 V).
Connection to the grounded conductor is not necessary.
Plug connection without grounded conductor contact.
Содержание EHB 11 BLS
Страница 1: ...Operator s manual Electric hammer EHB 11 BL BLM BLS 0212727en 002 05 2008...
Страница 2: ......
Страница 17: ...EHB 11 Safety information 17 For all other machines Item Label Description 1 Sound power level...
Страница 50: ......
Страница 53: ......
Страница 54: ......