Maintenance
Maintenance work 12.3
47
[us] | 06/2020 | 5100056974 | AS | Operator’s manual
12.3
Maintenance work
12.3.1
Carrying out preparations
CAUTION
Health risk from fuel, lubricants and coolants!
►
Do not inhale vapors.
►
Avoid skin and eye contact.
1.
Place the machine on a level surface.
2.
Decommissioning the machine.
3.
Remove the rechargeable battery.
4.
Let the machine cool down.
12.3.2
Cleaning the machine
NOTICE
Damage by penetrating water!
Penetrating water can damage electrical operating elements or machine
components.
Penetrating moisture can lead to total failure.
►
Do not clean the machine with high pressure or steam cleaners!
►
Use a cloth to remove water that has entered (e.g. due to rain) the
housing and then let the machine dry.
►
Only use dry and clean cloths.
NOTICE
Information on damage to the components!
Contact Wacker Neuson Service if the rechargeable battery or charger is
damaged.
1.
Clean machine and components after each use.
2.
Wacker Neuson recommends using compressed air to clean.
3.
Wipe the housing with a damp and clean cloth.
4.
Wipe the rechargeable battery and battery charger with a dry clean
cloth.
5.
After cleaning, check cables and wires for damage.
6.
Check screws and bolts to see if they are loose.
7.
Remedy any deficiencies noted immediately.