Operation
Putting out of operation 11.4
43
[us] | 06/2020 | 5100056974 | AS | Operator’s manual
Number of illuminated LEDs:
Charge condition of the
rechargeable battery
one
charge condition 0 - 20 %
two
charge condition > 20 %
three
charge condition > 40 %
four
charge condition > 60 %
five
charge condition > 80 %
six
rechargeable battery is fully
charged.
Information
Automatic shutdown of rechargeable battery!
If not started up, the rechargeable battery automatically switches off after
30 seconds.
11.4
Putting out of operation
WARNING
Warning of hot surfaces!
Crankcases with engine and guide cylinder can heat up after a short time,
which can lead to severe burns if they come into contact with the skin.
►
Always allow the machine to cool down after use.
►
If the cooling phase cannot be maintained (e.g. due to an emer-
gency) - use heat-resistant protective gloves.
1
2
3
1
Start button Activation/deactivation
2
Start lever
3
Safety lever
1.
Slowly pull the start lever
2
back until it stops.
ð
Safety lever
3
clicks into place with the start lever and holds it in
the OFF position.
2.
Allow the machine to come to a complete stop.
3.
Press start button activation/deactivation
1
.
CAUTION
Risk of injury from falling machine!
►
Secure the machine against tipping over, falling down or slipping,
e.g. in a closed container.
11