![WACKER Group LTC 4 Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/wacker-group/ltc-4/ltc-4_repair-manual_3103474124.webp)
Electrical Troubleshooting Procedures
LTC Repair
wc_tx000429gb.fm
120
7.28 Checking Stator Windings
See Graphic: wc_gr003097
The generator terminal block is located on top of the generator. When
checking the stator windings at the terminal block, if there is any
evidence of burned windings (such as melted wire insulation or odor),
replace the generator.
Carry out the following tests with the engine shut down.
Note: Before making resistance measurements, determine the value
of your meter’s internal resistance by touching the meter’s leads.
Subtract this value from the values you measure.
7.28.1
Remove the RED, BLACK, and WHITE wires from the generator
terminal block.
7.28.2
Remove the leads from the capacitors and place an insulated
screwdriver across the capacitors to discharge them.
7.28.3
Using the Ohm (resistance) setting on the multimeter, measure the
resistance T1 to T2. Also measure resistance T4 to T5. In both cases
the resistance measured should be 0.36 +0.5/-0.0 Ohms. Measure the
resistance #60 lead to #0 lead. The resistance measured should be 1.7
+0.5/-0.0 Ohms. If there is no continuity (meter reads “OPEN” or “OL”),
replace the stator.
7.28.4
Using the Ohm setting on the multimeter, measure the resistance T1
to ground, and T5 to ground. The multimeter should read “OPEN” or
“OL” for both tests. If the meter does not read “OPEN”, replace the
entire generator.
7.28.5
Using the Ohm scale on the multimeter, measure resistance #60 lead
to ground, #60 lead to T1, and #60 lead to T5. The multimeter should
read “OPEN” or “OL” for all three tests. If the meter does not read open,
replace the entire generator. Consult with factory to confirm.
Note: Do not touch the machine frame when making this test. A
reading error will occur.
Note: A meter reading of 2 megohms (2 M Ohms) or larger is
acceptable.
For a more thorough insulation test, use a megger meter capable of
500 Volts or have a motor repair shop test it. If readings are 2
megohms or greater, the stator is good. If readings are less than 2
megohms, replace the generator end. Consult factory to confirm.
Содержание LTC 4
Страница 1: ...www wackergroup com Light Tower LTC 4 REPAIR MANUAL 0160487en 003 0206 0 1 6 0 4 8 7 E N...
Страница 2: ......
Страница 9: ...LTC Repair Table of Contents wc_br0160487en_003TOC fm 5...
Страница 15: ...LTC Repair Safety Information wc_si000164gb fm 11 1 6 Label Locations...
Страница 16: ...Safety Information LTC Repair wc_si000164gb fm 12...
Страница 21: ...LTC Repair Safety Information wc_si000164gb fm 17 Q Ref Label...
Страница 26: ...Technical Data LTC 4 wc_td000157gb fm 22 Notes...
Страница 69: ...LTC Repair Lombardini Engine Troubleshooting wc_tx000364gb fm 65 wc_gr003228 30 50 B L V 15 54 d c a b...
Страница 93: ...LTC Repair Caterpillar Engine Troubleshooting wc_tx000476gb fm 89...
Страница 105: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 101 1000 200 20 2 200m F V A V COM wc_gr003095 b a c...
Страница 109: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 105 wc_gr002472 1000 200 20 2 200m F V A V COM a c b...
Страница 115: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 111 wc_gr003072 c d a b d c e e...
Страница 117: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 113 wc_gr002442 a d f g c b e...
Страница 123: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 119...
Страница 139: ...LTC Repair ElectricalTroubleshooting wc_tx000429gb fm 135 wc_gr003100 1000 200 20 2 200m F V A V COM b a c...
Страница 142: ...Electrical Troubleshooting Procedures LTC Repair wc_tx000429gb fm 138 Notes...
Страница 145: ...LTC Repair Disassembly Assembly Procedures wc_tx000428gb fm 141 a b c d g f e h j k i l m n o wc_gr002430 p q r t s...
Страница 153: ...LTC Repair Disassembly Assembly Procedures wc_tx000428gb fm 149 c a b c e d f h i j g wc_gr002434...
Страница 155: ...LTC Repair Disassembly Assembly Procedures wc_tx000428gb fm 151 h k i j l d a f g b e wc_gr002435 c...
Страница 157: ...LTC Repair Disassembly Assembly Procedures wc_tx000428gb fm 153 wc_gr003159 b c d e a f g...
Страница 159: ...LTC Repair Disassembly Assembly Procedures wc_tx000428gb fm 155 wc_gr002445 a b c e g k h i j d f...
Страница 165: ......