background image

WEL/ IM/ 05/ 18.03.2016 

 

15 

 

 
 

 

For cleaning of Modules Fresh water (TDS < 1500 mg/l) may be used. If needed, a mild, non-abrasive, 

non-caustic detergent with a final fresh water and detergent solution mix between 6.5 < pH < 8.5 at 25°C 
may be used. 

 

When  using  water,  RO  water  provides  the  best  results.  In  absence  of  RO  water,  tap  water  with  low 

mineral content (total hardness <75 mg/l) or deionized water may be used. Calcium should not exceed: 
75  mg/ml.  Do  not  use  solutions  containing  hydrochloric  acid,  D-Limonene,  ammonia  or  sodium 
hydroxide. 

 

Clean the Module either with a soft sponge or a soft rubber wiper. Do not use abrasive cleaners or de- 

greasers on the Module. Do not scrub the Module with abrasive brushes. Such brush fibers may scratch 
the glass, reducing the power output of the panel. 

 

In case if soft water (with low mineral content) is not available, Module can be dry cleaned with the help 

of a soft cloth or with soft sponge to remove dirt, dust. One can also use wet cloth, sponge to clean dirt 
which is not easily removed by dry cleaning. 

 

Do not clean or spray water at the Junction Box or any area on the backside of the Module. 

 

Frequency of Cleaning will vary depending upon any special conditions in  the area where the Modules 

are installed. Modules installed in high windy or dusty areas should be inspected more frequently. 

 

If excessive soiling is present, a non-conductive soft brush, sponge, or other mild agitating method may 

be used before using water. Ensure brushes or agitating tools are not abrasive to glass. 

 

Module damage that arises as a result of improper cleaning will not be warranted by WAAREE Energies 

Ltd. 

 

Do not clean the glass surface with chemicals. Do not let water stay on the glass surfaces of PV Modules 

for  a  long  time.  This  creates  a  risk  of  permanent  damage  to  the  glass,  such  as  white  efflorescence, 
otherwise known as “glass disease,” which may cause reduced power output. 

 

To avoid dirt accumulation or white efflorescence due to water accumulation, do not install PV Modules 

horizontally (flat). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAAREE ENERGIES LIMITED

 

602, Western Edge-I, Off. Western Express Highway 

Borivali (E), Mumbai 400066, Maharashtra, India 

Tel: +91-22-66444400 

[email protected]

 

 

 

 

 

 

 

 

Содержание PV Modules

Страница 1: ...fice 602 Western Edge I Off Western Express Highway Borivali E Mumbai 400066 Maharashtra India Tel 91 22 66444400 waaree waaree com Factory Address Plot No 231 236 Surat Special Economic Zone Diamond...

Страница 2: ...CAUTIONS FOR UNPACKING HANDLING STORAGE OF PV MODULE 5 CLIMATIC CONDITIONS 6 NOTES ON INSTALLATION 6 SPECIFICATIONS 7 SOLAR PV MODULE MOUNTING GUIDELINES 7 GROUNDING 10 ELECTRIC WIRING 11 CABLE PROTEC...

Страница 3: ...ed on our knowledge and experience and is believed to be reliable but such information including product specifications without limitations and suggestions do not constitute a warranty expressed or im...

Страница 4: ...d by qualified personnel only Children and unauthorized persons should not be allowed near the installation of PV Modules Use Module for its intended function only Be sure that all other system compon...

Страница 5: ...e Modules Avoid Module mishandling during unloading Do not stack more than the maximum amount of allowable pallets on top of each other At the installation site take care to keep Modules and particula...

Страница 6: ...o the Module output NOTES ON INSTALLATION Please read this guide completely before installation or use of the Modules Modules shall be mounted with the orientation and tilt angle required for consiste...

Страница 7: ...dule frames Since sparks may occur do not install the Module where flammable gases or vapors are present During installation all local and national electrical and building codes and regulations shall...

Страница 8: ...Aluminium Frame 2 M6 Stainless bolts 3 Flat Stainless washer 4 Spring Stainless washer 5 HEX Stainless Nut b Mounting guidelines for Clamping of Modules Each Module must be securely fixed to the mount...

Страница 9: ...fety it is better to follow the clamp manufacturer s recommendations Clamp types Mid clamps They hold each neighbouring panel on the purlin End clamps They hold the panel at fringes at their position...

Страница 10: ...racks must be properly grounded in accordance with respective national electrical code The earth grounding connection shall be done by a qualified electrician The longer sides of the Module frames are...

Страница 11: ...n accordance with applicable electrical codes All wiring should be done by a qualified licensed professional Wiring should be protected to help ensure personal safety and to prevent its damage Modules...

Страница 12: ...e with appropriate precautions e g locate them within plastic conduit Avoid exposure to the direct sunlight Ensure that the cables will be away from areas where water can form puddles When disconnecti...

Страница 13: ...the frame do not treat back sheet and front surface of the Module with paint and adhesives Do not artificially concentrate light on the Module GENERAL SAFETY Follow all permission installation and in...

Страница 14: ...late on the surface of the Module This can reduce the optimal output performance of the solar Modules Normally the accumulated dust can be washed with water but in some instances some maintenance is r...

Страница 15: ...irt which is not easily removed by dry cleaning Do not clean or spray water at the Junction Box or any area on the backside of the Module Frequency of Cleaning will vary depending upon any special con...

Отзывы: