background image

WEL/ IM/ 05/ 18.03.2016 

 

 

 

 

 

A Sample drawing is shown for installation of Module

 

 

 

 

 

(a) Mounting guidelines for Bolting of Modules:-

 

 

Modules must be mounted on mounting holes located at rear side with the M6 stainless steel nut, bolt and 
washer.  It  is  recommended to  use  stainless  steel  fixing  only.  Module  mounting  must  use  the  pre-drilled 
mounting holes in the frame. Always select the length of mounting screw after considering a clearance of 5- 
10 mm between the Module back face & screw face to avoid any breakage of Module while tightening. 

 

Note: - 

Do not drill additional mounting holes on the frame & glass surface of the Module.

 

Doing so will void the warranty.

 

 

 

 

1.  Aluminium Frame 
2.  M6 Stainless bolts 
3.  Flat Stainless washer 
4.  Spring Stainless washer 
5.  HEX Stainless Nut 

 

 

 

 

 

 

 

 

 

(b) Mounting guidelines for Clamping of Modules:-

 

 

Each Module must  be securely fixed to  the mounting structure at  a minimum of four points. The  Module 

clamps shall not come into contact with the front glass and must not deform the frame. Be sure to avoid 

shadowing   effects   from   the   Module   clamps.   The   Module   frame   is   not   to   be   modified   under   any 

circumstances.  When  choosing  this  type  of  clamp-mounting  method,  please  be  sure  to  use  at  least  four 
clamps on each Module, two clamps should be attached on each long sides and 2 clamps on each short side 
of  the  Module.  Depending  on  the  local  wind  and  snow  loads,  if  excessive  pressure  load  is  expected, 
additional clamps or support would be required to ensure that the Module can bear the load. The applied  

Содержание PV Modules

Страница 1: ...fice 602 Western Edge I Off Western Express Highway Borivali E Mumbai 400066 Maharashtra India Tel 91 22 66444400 waaree waaree com Factory Address Plot No 231 236 Surat Special Economic Zone Diamond...

Страница 2: ...CAUTIONS FOR UNPACKING HANDLING STORAGE OF PV MODULE 5 CLIMATIC CONDITIONS 6 NOTES ON INSTALLATION 6 SPECIFICATIONS 7 SOLAR PV MODULE MOUNTING GUIDELINES 7 GROUNDING 10 ELECTRIC WIRING 11 CABLE PROTEC...

Страница 3: ...ed on our knowledge and experience and is believed to be reliable but such information including product specifications without limitations and suggestions do not constitute a warranty expressed or im...

Страница 4: ...d by qualified personnel only Children and unauthorized persons should not be allowed near the installation of PV Modules Use Module for its intended function only Be sure that all other system compon...

Страница 5: ...e Modules Avoid Module mishandling during unloading Do not stack more than the maximum amount of allowable pallets on top of each other At the installation site take care to keep Modules and particula...

Страница 6: ...o the Module output NOTES ON INSTALLATION Please read this guide completely before installation or use of the Modules Modules shall be mounted with the orientation and tilt angle required for consiste...

Страница 7: ...dule frames Since sparks may occur do not install the Module where flammable gases or vapors are present During installation all local and national electrical and building codes and regulations shall...

Страница 8: ...Aluminium Frame 2 M6 Stainless bolts 3 Flat Stainless washer 4 Spring Stainless washer 5 HEX Stainless Nut b Mounting guidelines for Clamping of Modules Each Module must be securely fixed to the mount...

Страница 9: ...fety it is better to follow the clamp manufacturer s recommendations Clamp types Mid clamps They hold each neighbouring panel on the purlin End clamps They hold the panel at fringes at their position...

Страница 10: ...racks must be properly grounded in accordance with respective national electrical code The earth grounding connection shall be done by a qualified electrician The longer sides of the Module frames are...

Страница 11: ...n accordance with applicable electrical codes All wiring should be done by a qualified licensed professional Wiring should be protected to help ensure personal safety and to prevent its damage Modules...

Страница 12: ...e with appropriate precautions e g locate them within plastic conduit Avoid exposure to the direct sunlight Ensure that the cables will be away from areas where water can form puddles When disconnecti...

Страница 13: ...the frame do not treat back sheet and front surface of the Module with paint and adhesives Do not artificially concentrate light on the Module GENERAL SAFETY Follow all permission installation and in...

Страница 14: ...late on the surface of the Module This can reduce the optimal output performance of the solar Modules Normally the accumulated dust can be washed with water but in some instances some maintenance is r...

Страница 15: ...irt which is not easily removed by dry cleaning Do not clean or spray water at the Junction Box or any area on the backside of the Module Frequency of Cleaning will vary depending upon any special con...