VWR SCCP-19 Скачать руководство пользователя страница 22

 

Part number 20047, Rev 0

 

22 

 

WARRANTY IS NOT TRANSFERABLE.

  This warranty is not assignable and applies only in favor of the 

original purchaser/user to whom delivered.  Any such assignment or transfer shall void the warranties 
herein made and shall void all warranties, express or implied, including any warranty of merchantability 
or fitness for a particular purpose. 

NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

  There are 

no other warranties, express, implied, or statutory, except the two (2) year warranty and the additional 
three (3) year compressor warranty as described above.  These warranties are exclusive and in lieu of all 
other warranties, including implied warranty and merchantability or fitness for a particular purpose.  
There are no warranties which extend beyond the description on the face hereof, whether based on 
contract, warranty, tort (including negligence), strict liability, indemnity, or any other legal theory, and 
whether arising out of warranties, representations, instructions, installations, or non-conformities from 
any cause.  Purchaser further acknowledges that the purchase price of the Product reflects these 
warranty terms and remedies. 

ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, 
FIRE, FLOOD OR OTHER EXTERNAL CAUSES.

   

Horizon Scientific, Inc. is not responsible for the repair or replacement of any parts that Horizon 
Scientific, Inc. determines have been subjected after the date of manufacture to alteration, neglect, 
abuse, misuse, accident, damage during transit or installation, fire, flood or other external causes.  It 
does not apply to defects resulting from failure to properly install, operate or maintain the product in 
accordance with the printed instructions provided, or damage caused by the storage of any corrosive 
material that comes in contact with the interior or exterior portions of the cabinet, or the use of spark 
producing equipment or containers (such as galvanized or carbonized steel containers) that come in 
contact with any interior portion of the cabinet. 

OUTSIDE U.S./CANADA.

  This warranty does not apply to, and Horizon Scientific, Inc. is not responsible 

for, any warranty claims made on products sold or used outside the United States and Canada. 

CHOICE OF LAW/VENUE.  

The laws of the State of South Carolina shall govern the validity, interpretation 

and enforcement of this warranty, regardless of conflicts of law principles.  Purchaser agrees that proper 
venue for any action to enforce the terms of this warranty shall be the Dorchester County District 
Courts, South Carolina.  Purchaser submits the jurisdiction of such courts over the Purchaser and the 
subject matter of any such action.  Any action for breach of these warranty provisions must be 
commenced within one (1) year after that cause of action has accrued. 

WARRANTY CLAIMS.

  To obtain prompt warranty service, simply contact the manufacturer at 800-648-

4041.  Horizon Scientific, Inc.’s

 

shipping records showing date of shipment shall be conclusive in 

establishing the warranty period.  All claims should include:  model number of the refrigerator, the serial 
number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting 
the existence of the alleged defect.  Any repairs must be authorized by Horizon in order for the warranty 
to be honored.

 

 

 

 
 

Содержание SCCP-19

Страница 1: ...agent driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is...

Страница 2: ...MANUFACTURER S TECHNICAL SERVICE DEPARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can b...

Страница 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Страница 4: ...t needed PLEASE NOTE Your refrigerator or freezer is designed as INDOOR USE and should be operated at air conditioned room temperature between 65 F to 85 F Remove the lower grill assembly from the fro...

Страница 5: ...the plastic door stoppers see Image 4 5 and 6 CASTERS INSTALLATION It is important to ensure the casters are installed properly and securely in order to obtain the maximum strength and stability of th...

Страница 6: ...on cord Be sure your unit is properly grounded Use the 3 prong plug provided into a 3 prong grounded outlet Only this method complies with national electrical codes local codes and ordinances Unless t...

Страница 7: ...nd product temperatures inside of the units and require no further adjustment Please contact the manufacturer s Technical Support Department before making any adjustment to make sure the adjustment is...

Страница 8: ...king the evaporator fan s if installed There should be at least 4 inches of clearance below the fan s to allow proper air flow Do not overload the unit Maximum suggested load is about 75 of chamber ca...

Страница 9: ...ated with the alarm system i e delay times system status a battery backup which will maintain the alarm system for several hours after a power failure to allow for continued alarm and notification fun...

Страница 10: ...pressed The MUTE PROGRAM button has three functions In Normal Run mode if the unit is beeping pressing the button will mute the beeper for a preset time Each time the button is pressed the mute time r...

Страница 11: ...the BEEPER and ALARM LED will both activate Press the MUTE PROGRAM button to stop the beeper for a specified time changing the sound to short chirps When the temperature goes back within range and the...

Страница 12: ...n a short period 5 Once the Monitor is in Programming mode each time the Mute button is pressed the display steps to the next parameter As the display steps to the next parameter the value of the prev...

Страница 13: ...mote Alarm Relay is a single pole double throw SPDT relay that changes state switches with the loss of line power or with the presence of an alarm condition NOTE The relay is rated for pilot duty oper...

Страница 14: ...of the unit A touch keypad allows the user to easily select the display units set point differential set point and heating or cooling mode Please Note The digital temperature controller has been fact...

Страница 15: ...et point and S1 will be blinking Press the up and down keys to adjust to the desired setting S1 blinking Setpoint Temperature Press SET key again to access the differential mode The LCD will display t...

Страница 16: ...y EP Appears when the probe is open shorted or sensing a temperature that is out of range Check to see if the sensed temperature is out of range If not check for probe damage by comparing it to a know...

Страница 17: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Страница 18: ...prevent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURIN...

Страница 19: ...sehold cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smooth handles Do not use a dry cloth to clean smooth handles For Glass Door Units clean the glass with a mild detergent a...

Страница 20: ...th pressurized air CO2 or nitrogen REMEMBER THE CLEANING OF THE CONDENSER IS NOT COVERED BY THE WARRANTY AND IS YOUR RESPONSIBILITY ANY DAMAGE CAUSED BY FAILURE TO KEEP THE CONDENSER CLEAN IS ALSO NOT...

Страница 21: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Страница 22: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Отзывы: