12.  Repair and maintenance

Microscopy environment

This microscope is recommended for use in a clean, dry and shock free environment with a temperature of 

0-40°C and a maximum relative humidity of 85 % (non condensing). Use a dehumidifier if needed.

To think about when and after using the microscope

The microscope should always be kept vertical when moving it so that no moving parts, such as the eyepieces, 

fall out. Never mishandle or impose unnecessary force on the microscope.

Never attempt to service the microscope yourself.

After use, turn down the illumination intensity control and turn the light off. Cover the microscope with included 

the dust cover, and keep it in a dry and clean place.

Electrical safety precautions

Before plugging in the power supply, make sure that the supplying voltage of your region matches with the ope-

ration voltage of the equipment and that the lamp switch is in off-position.

Users should observe all safety regulations of the region. The equipment has acquired the CE safety label. Ho-

wever, users do have full responsibility to use this equipment safely.

Cleaning the optics

If the optical parts require cleaning first use compressed air.

If that is not sufficient use a soft lint-free cloth with water and a mild detergent.

And as a final option use the piece of cloth moistened with a 3:7 mixture of ethanol and ether.

• 

Note: ethanol and ether are highly flammable liquids. Do not use them near a heat source, near sparks or 

near electric equipment. Use these chemicals in a well ventilated room.

Remember to never wipe the surface of any optical items with your hands. Fingerprints can damage the optics. 

Do not disassemble objectives or eyepieces attempting to clean them.

For the best results, use the VWR cleaning kit.

If you need to send the microscope to manufacturer for maintenance, please use the original packaging.

13.  Technical service

Web Resource
Visit the VWR’s website at 

www.vwr.com

 for:

•  Complete technical service contact information

•  Access to VWR’s Online Catalogue, and information about accessories and related products

• 

Additional product information and special offers

Contact us

 For information or technical assistance contact your local VWR representative or visit. 

www.vwr.

com.

14. Warranty

VWR International

 warrants that this product will be free from defects in material and workmanship for a period 

of five (5) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or 

refund the purchase price of this product to the customer, provided it is returned during the warranty period. This 

warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication, or from 

ordinary wear and tear. If the required maintenance and inspection services are not performed according to the 

manuals and any local regulations, such warranty turns invalid, except to the extent, the defect of the product is 

not due to such non-performance.
Items being returned must be insured by the customer against possible damage or loss. This warranty shall be 

limited to the aforementioned remedies. IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU 

OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY.

15.  Compliance with local laws and regulations

The customer is responsible for applying for and obtaining the necessary regulatory approvals or other authori-

zations necessary to run or use the Product in its local environment. VWR will not be held liable for any related 

omission or for not obtaining the required approval or authorization, unless any refusal is due to a defect of the 

product.

 

 

Содержание 630-3072

Страница 1: ...Model European Catalogue Number STB260 630 3072 SZB260 630 3073 SZT260 630 3074 INSTRUCTION MANUAL VWR Stereomicroscope series 260 Version 1 0 Issued 29 07 2019 1 2...

Страница 2: ...0 5 8 3 Assembling procedure 6 9 Use of the microscope 8 9 1 Adjust interpupillary distance 8 9 2 Focus 8 9 3 Adjusting the tension of the focus knob 8 9 4 Dioptric compensation 9 9 5 Magnification 9...

Страница 3: ...sure safe operation of the unit 3 Package Contents DESCRIPTION QUANTITY Stereomicroscope 1 Stereo head Binocular fixed zoom STB260 Binocular variable zoom SZB260 Trinocular variable zoom SZT260 1 Eyep...

Страница 4: ...with handle and focus Swiveling incident and transmitted with brightness control rechargeable batteries SZT260 Trinocular Widefield 10x 21mm 0 7x 4 5x variable zoom 100 mm High grade precision fixed...

Страница 5: ...B260 BINOCULAR SZT260 TRINOCULAR INCIDENT LIGHT ON OFF AND INTENSITY CONTROL TRANSMITTED LIGHT ON OFF AND INTENSITY CONTROL FOCUS KNOB INCIDENT LIGHT ILLUMINATOR STAGE CLIPS STAND TRANSLUCENT DISC TRA...

Страница 6: ...it is necessary to ship the mi croscope with the batteries disconnected 1 Open the lid of the battery compartment Fig 1 2 Insert the provided rechargeable batteries re specting the polarity of each ba...

Страница 7: ...Remove the eyepieces dust caps and insert the eyepieces in the empty eyepiece sleeve Fig 5 7 Connect the jack of the power supply to the sock et in the rear part of the microscope base Fig 6 Fig 5 Fi...

Страница 8: ...erved on the stage plate and focus the sample using the focusing knobs of the stand Fig 8 9 3 Adjusting the tension of the focus knob This adjustment allows to increase or decre ase the tension of the...

Страница 9: ...or the whole zoom range It should now be perfectly parfocal focus is always maintained during the change of magnification 9 5 Magnification STB260 1 Rotate the magnification changer to insert the desi...

Страница 10: ...X W D 114 mm 5 25X 33 75X 40 6 21 7 87X 50 62X 19 06 2 96 10 50X 67 5X 9 52 1 48 1X W D 100 mm 7X 45X 29 99 4 66 10 5X 67 5X 10 95 2 22 14X 90X 7 14 1 11 1 5X W D 47 mm 10 50X 67 5X 20 3 10 15 75X 101...

Страница 11: ...urn ON OFF or to change the intensity of the transmit ted light LED Fig 18 2 Turn the incident light knob in order to turn ON OFF or to change the intensity of the incident light LED It is possible to...

Страница 12: ...apter into the relay tube 2 Screw the T2 ring not provided to the reflex adapter 3 Connect the Reflex camera to the T2 ring just installed Fig 24 4 Install the other end of the relay tube into the mic...

Страница 13: ...adjustment collar is too tight Loosen the tension adjustment collar The focus is unstable The tension adjustment collar is too loose Tighten the tension adjustment collar III Electric Section The LED...

Страница 14: ...e best results use the VWR cleaning kit If you need to send the microscope to manufacturer for maintenance please use the original packaging 13 Technical service Web Resource Visit the VWR s website a...

Страница 15: ...ur responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recyclin...

Страница 16: ...thwest Business Park Ballycoolin Dublin 15 Tel 01 88 22 222 Fax 01 88 22 333 E mail sales ie vwr com Italy VWR International PBI S r l Via San Giusto 85 20153 Milano MI Tel 02 3320311 02 487791 Fax 80...

Отзывы: