Model
European Catalogue Number
STB260
630-3072
SZB260
630-3073
SZT260
630-3074
INSTRUCTION MANUAL
VWR
Stereomicroscope
series 260
Version:
1.0
Issued:
29, 07, 2019
1/2
Страница 1: ...Model European Catalogue Number STB260 630 3072 SZB260 630 3073 SZT260 630 3074 INSTRUCTION MANUAL VWR Stereomicroscope series 260 Version 1 0 Issued 29 07 2019 1 2...
Страница 2: ...0 5 8 3 Assembling procedure 6 9 Use of the microscope 8 9 1 Adjust interpupillary distance 8 9 2 Focus 8 9 3 Adjusting the tension of the focus knob 8 9 4 Dioptric compensation 9 9 5 Magnification 9...
Страница 3: ...sure safe operation of the unit 3 Package Contents DESCRIPTION QUANTITY Stereomicroscope 1 Stereo head Binocular fixed zoom STB260 Binocular variable zoom SZB260 Trinocular variable zoom SZT260 1 Eyep...
Страница 4: ...with handle and focus Swiveling incident and transmitted with brightness control rechargeable batteries SZT260 Trinocular Widefield 10x 21mm 0 7x 4 5x variable zoom 100 mm High grade precision fixed...
Страница 5: ...B260 BINOCULAR SZT260 TRINOCULAR INCIDENT LIGHT ON OFF AND INTENSITY CONTROL TRANSMITTED LIGHT ON OFF AND INTENSITY CONTROL FOCUS KNOB INCIDENT LIGHT ILLUMINATOR STAGE CLIPS STAND TRANSLUCENT DISC TRA...
Страница 6: ...it is necessary to ship the mi croscope with the batteries disconnected 1 Open the lid of the battery compartment Fig 1 2 Insert the provided rechargeable batteries re specting the polarity of each ba...
Страница 7: ...Remove the eyepieces dust caps and insert the eyepieces in the empty eyepiece sleeve Fig 5 7 Connect the jack of the power supply to the sock et in the rear part of the microscope base Fig 6 Fig 5 Fi...
Страница 8: ...erved on the stage plate and focus the sample using the focusing knobs of the stand Fig 8 9 3 Adjusting the tension of the focus knob This adjustment allows to increase or decre ase the tension of the...
Страница 9: ...or the whole zoom range It should now be perfectly parfocal focus is always maintained during the change of magnification 9 5 Magnification STB260 1 Rotate the magnification changer to insert the desi...
Страница 10: ...X W D 114 mm 5 25X 33 75X 40 6 21 7 87X 50 62X 19 06 2 96 10 50X 67 5X 9 52 1 48 1X W D 100 mm 7X 45X 29 99 4 66 10 5X 67 5X 10 95 2 22 14X 90X 7 14 1 11 1 5X W D 47 mm 10 50X 67 5X 20 3 10 15 75X 101...
Страница 11: ...urn ON OFF or to change the intensity of the transmit ted light LED Fig 18 2 Turn the incident light knob in order to turn ON OFF or to change the intensity of the incident light LED It is possible to...
Страница 12: ...apter into the relay tube 2 Screw the T2 ring not provided to the reflex adapter 3 Connect the Reflex camera to the T2 ring just installed Fig 24 4 Install the other end of the relay tube into the mic...
Страница 13: ...adjustment collar is too tight Loosen the tension adjustment collar The focus is unstable The tension adjustment collar is too loose Tighten the tension adjustment collar III Electric Section The LED...
Страница 14: ...e best results use the VWR cleaning kit If you need to send the microscope to manufacturer for maintenance please use the original packaging 13 Technical service Web Resource Visit the VWR s website a...
Страница 15: ...ur responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recyclin...
Страница 16: ...thwest Business Park Ballycoolin Dublin 15 Tel 01 88 22 222 Fax 01 88 22 333 E mail sales ie vwr com Italy VWR International PBI S r l Via San Giusto 85 20153 Milano MI Tel 02 3320311 02 487791 Fax 80...