MULTI GAS LEAK DETECTOR
ME-LOKATOR VL30 – REFRIGERANT GASES
PAGE |
4
LOKATOR VL 30 EN
3.2.1
FRONT PANEL OF ELECTRONIC UNIT
1
> light ramp
6
> mains supply indicator light
2
> self cheking light
7
> battery charge indicator light
3
> 4 lines LCD screen
9
> power on indicator light
4
> volume adjustment
9
> start-up push button
5
> connector for double-plug cable
10
> RESET hole
11
> directional selection pad
3.2.2
REAR PANEL OF ELECTRONIC UNIT
1
> ventilation opening
2
> main power switch
3
> fuse 500 mA
4
> mains power socket 110v to 250v 50/60Hz
3.2.3
LEFT PANEL OF ELECTRONIC UNIT
1
> Logic output DB9 socket
• 1: Ready to Detect • 2: Busy
• 3: Error
• 4: Detection
• 5: Detec. Threshold • 6: Contamination
• 7: N/A
• 8: GND – 0v
• 9: 12v
The logic outputs can be used directly on an automatic system. The logic signals are of type
[0v - 5v] max 5 mA.
Do not use outputs directly to operate relays.
Use in this case the Power Box.
Ref : MTD930-BP6R [in OPTION]
3.2.4
DUAL CONNECTOR CABLE
Dual-plug cable connecting the probe to the electronic unit. The cable connects on the front face
cabinet [chap. 3.2.1
N°5
]. The standard cable length is 2.50 m. Cable Length of 5 m and 10 m
available on request.
4
5
6
7
9
1
1
2
3
4
3
2
8
1
10
11