MULTI GAS LEAK DETECTOR
ME-LOKATOR VL30 – REFRIGERANT GASES
PAGE |
9
LOKATOR VL 30 EN
YELLOW LIGHT
At the beginning of the light ramp. These lights indicate
« x.3 x.2 »
the presence of leakage less than the set point.
• x.3 > detection 3 times lower than the threshold value « S »
• x.2 > detection 2 times lower than the threshold value « S »
RED LIGHT
Illuminates for the threshold value corresponding to the indicated value
« S »
on the LCD screen. [chap. 5.2.2]
• Turning the light on the Remote Detection unit.
• Triggering the 1st tone sound.
RED LIGHT
Lights up for the threshold value greater than the value indicated on
« x2 x3 x5 x7 »
the LCD screen.
• x2 > detection 2 times higher than the threshold value « S »
• x3 > detection 3 times higher than the threshold value « S »
• x5 > detection 5 times higher than the threshold value « S »
• x7 > detection 7 times higher than the threshold value « S »
YELLOW LIGHT
Leakage Value Detected 10 times the threshold value.
« CONTAMINATION »
Indicates the SATURATION/CONTAMINATION of the cell.
« x10 »
5.2.2
DETECTION SCREEN
1
> Profile gas in use (ex. Profile A R32)
2
> Profile detection threshold in use.
3
> CALIBRATION Menu
4
> Battery level display [BATTERY Option]
5
> Select and activate Profile B
6
> OPTIONS Menu
• PROFILE GAS IN USE
Gas corresponding to active profile A or B. Profiles A and B can be configured in the "OPTIONS" menu. [chap. 6.2]
• PROFILE DETECTION THRESHOLD IN USE
Detection threshold corresponding to active profile A or B. The value of the indicated threshold corresponds to the leakage
value for which the red "S" indicator will light up. Profiles A and B can be configured in the "OPTIONS" menu. [chap. 6.2]
• CALIBRATION MENU
Provides access to the LOKATOR VL30 calibration procedure. [chap. 5.4]
• BATTERY LEVEL display
Indicates the charge level of the internal battery of the LOKATOR VL30 : 100%, 75%, 50%, 25%, 10%.
Only works with the built-in battery pack option. [chap. 4.1.4]
• OPTIONS MENU
Used to switch between active profiles, between profile A and B. Profiles A and B can be configured in the "OPTIONS" menu.
[chap. 6.2]
• OPTIONS MENU
Provides access to the various setting options of the LOKATOR VL30. [chap. 6]