MULTI GAS LEAK DETECTOR
ME-LOKATOR VL30 – REFRIGERANT GASES
PAGE |
3
LOKATOR VL 30 EN
3
DESCRIPTION OF THE APPLIANCE
3.1
FUNCTIONALITIES
The LOKATOR VL30 provide the following functions:
GENERAL
• Selection in a list of detected gas
• Automatic Calibration
• Display of estimated leakage value in g/year
INTERFACE / DISPLAY
• 4 lignes LCD screen
• Two configurable sensitivity profiles
• Light ramp with 3-tone sound signal
• Saturation indication if leak detection is 10 times the set value
• Degassing Countdown timer
• Adjustable sound volume
• Indication of environmental contamination
SELF-CHECKING
• Permanent self-checking
• Self-checking of the Detection Cell
• Short-circuit protection in the double-plug cable.
COMMUNICATION
• Logic output DB9 socket - 6 signals: #Ready to Detect #Busy #Error
#Detection #Detection threshold #Contamination
3.2
DETECTOR MODULES
The apparatus consists of 3 modules:
• 1 Electronic box
• 1 double-socket cable, connecting the Detection Block to the electronic box
• 1 Detection Block: Suction Block + Detection Cell + Semi-rigid Pipe
The sniffing pipe has a standard length of 13 cm.
Special length pipes can be supplied according to customer needs.
• Electronic unit
• Double-socket cable
• 1 Detection Block