background image

V-SERIES HEAVY DUTY
BROILERS, DOUBLE DECK AND
RANGE MATCH MODELS

For a complete listing of models, see the MODELS
section.

- NOTICE -

This  Manual  is  prepared  for  the  use  of  trained  Vulcan  Service
Technicians  and  should  not  be  used  by  those  not  properly
qualified.

This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not  have  the  necessary  tools,  instruments  and  skills  should  be
performed by a trained Vulcan Service Technician.

The  reproduction,  transfer,  sale  or  other  use  of  this  Manual,
without the express written consent of Vulcan, is prohibited.

This manual has been provided to you by ITW Food Equipment
Group LLC ("ITW FEG") without charge and remains the property
of ITW FEG, and by accepting this manual you agree that you will
return it to ITW FEG promptly upon its request for such return at
any time in the future.

SERVICE MANUAL

A product of Vulcan-Hart

3600 North Point Blvd Baltimore, MD 21222

F45548 (0715)

Содержание VBB1BF

Страница 1: ...tools instruments and skills required to perform the procedure Procedures for which you do not have the necessary tools instruments and skills should be performed by a trained Vulcan Service Technici...

Страница 2: ...BURNER 8 INFRARED BURNER 10 GAS PRESSURE REGULATOR 10 RACK SPRINGS 10 SERVICE PROCEDURES AND ADJUSTMENTS 12 PILOT FLAME HEIGHT 12 CERAMIC RADIANT BURNER AIR SHUTTER ADJUSTMENT 12 REGULATOR ADJUSTMENT...

Страница 3: ...ers Operations Manual sent with each unit The manual is also available online at www vulcanequipment com RACK POSITION AND GAS SETTING NOTE Infrared burner models must use the full gas setting knob fu...

Страница 4: ...lly Assemble the parts and retain for future use on gas equipment Pipe tee sized for the gas line inlet connection and pipe fittings pipe nipples reducers etc for the connection as required Hose barb...

Страница 5: ...must be checked for leaks Check with a soap and water solution bubbles Do not use an open flame Accessing Control Valve Upper Broiler double stack or single unit over range The side panel must be remo...

Страница 6: ...ews at the rear that are securing the back panel 1 Fig 6 and side panel to broiler frame Arrows shown in Fig 6 are pointing to the rear screw locations for right side panel removal Fig 6 D Remove side...

Страница 7: ...ilot tube fitting and remove the tube Fig 9 When disconnecting compression nut from the pilot tube fitting support the fitting to prevent damage to pilot tubing 5 Reverse procedure to install and chec...

Страница 8: ...ach burner 3 Fig 12 There are 6 ceramic bricks for each of the 3 burners 18 bricks total Fig 12 5 Remove screws securing pilot tube mounting brackets 1 Fig 13 to burner support 2 Fig 13 Position pilot...

Страница 9: ...nto the broiler grid Position 2 x 4 s underneath the burners near the front Fig 18 11 Adjust rack assembly to the middle position 12 Remove cotter pin from all three burners Fig 19 13 Grasp the bottom...

Страница 10: ...flame Clean pipe threads and apply thread sealant that is suitable for use with propane gases NOTE Gas pressure regulator should be installed as close to the broiler inlet gas connection as possible 1...

Страница 11: ...n springs Fig 24 3 Remove springs from the lifting arm mechanism and eye bolt 4 Reverse procedure to install 5 Perform RACK SPRING TENSION ADJUSTMENT V SERIES HEAVY DUTY BROILERS DOUBLE DECK AND RANGE...

Страница 12: ...stics and excessive gas consumption may occur An air shutter on the front of the burner controls the gas mixer balance A yellow streaming flame on the burner is an indication of insufficient primary a...

Страница 13: ...wise to decrease pressure until the proper gas pressure is achieved C Install the regulator closing nut D Turn gas supply off E Remove manometer and tee from gas line Clean pipe threads and apply thre...

Страница 14: ...base of the valve stem See LUBRICATION If valve grease does not improve rotation of the valve or damage is found replace the CONTROL VALVE as outlined under REMOVAL AND REPLACEMENT OF PARTS RACK SPRIN...

Страница 15: ...gas pressure 3 Control valve malfunction CERAMIC RADIANT BURNER CERAMIC RADIANT BURNER SYMPTOM POSSIBLE CAUSE Flame too yellow 1 Orifice incorrect size or dirty 2 Air shutter not adjusted correctly o...

Страница 16: ...r not lighting properly or incorrect burner flame appearance due to clogged ports 1 Broiler with Infrared burner is located too close to a fryer or charbroiler and the grease laden air is causing burn...

Отзывы: