– 25 –
GAS PRESSURE ADJUSTMENT
WARNING: DISCONNECT (UNPLUG) ELECTRICAL
POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING YOU ARE
WORKING ON THE CIRCUIT.
Accurate gas pressure adjustments can only be
made with the gas on and the burner lit. If the
incoming line pressure to the valve is less than the
minimum stated, then the manifold pressure cannot
be set correctly.
1. Turn gas supply off at manual shutoff valve.
2. Remove the right side panel as outlined
under Covers and Panels in Removal and
Replacement of Parts.
3. Remove the plug from the manifold pressure
port.
4. Install hose barb adapter and attach
manometer tube.
5. Remove adjustment screw cap from the gas
valve and turn gas supply to the oven back
on.
WARNING: THE FOLLOWING STEPS REQUIRE
POWER TO BE APPLIED TO THE UNIT DURING
TEST. USE EXTREME CAUTION AT ALL TIMES.
6. Plug the unit in and turn the power switch ON.
7. Set the temperature controller to its highest
setting and allow burner to ignite. The burner
must be lit during test and adjustment.
8. Turn the set screw to obtain the proper gas
pressure (clockwise = pressure increase;
counterclockwise = pressure decrease).
S
A
G
E
P
Y
T
)
.
C
.
W
N
I
(
S
G
N
I
D
A
E
R
E
R
U
S
S
E
R
P
D
L
O
F
I
N
A
M
E
N
I
L
D
E
D
N
E
M
M
O
C
E
R
N
I
M
X
A
M
l
a
r
u
t
a
N
5
.
3
0
.
7
0
.
5
4
1
e
n
a
p
o
r
P
0
1
0
.
1
1
0
.
1
1
Содержание SG4C ML-114876
Страница 2: ...2 VULCAN HART COMPANY 2002...
Страница 38: ...38 WIRING DIAGRAMS WIRING DIAGRAM SG4D SG6D OVENS 120 200 V 424372 Rev F...
Страница 39: ...39 WIRING DIAGRAM 734 COMPUTER CONTROL DUAL BURNER CONVECTION OVENS 120 200 V 426574 Rev C...
Страница 40: ...40 SCHEMATICS GAS CONVECTION OVEN SG4 WITH STD CONTROL 424373 1 REV C...
Страница 41: ...41 GAS CONVECTION OVEN SG4 WITH WATLOW 734 CONTROL 426575 1 REV C...