IGNITION CONTROL MODULE
WARNING: DISCONNECT (UNPLUG) ELECTRICAL
POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING YOU ARE
WORKING ON THE CIRCUIT.
1. Remove the right side cover as outlined
under Covers and Panels.
2. Loosen the screws securing the mounting
bracket to the component panel and remove
the bracket.
3. Disconnect the lead wires and igniter cables
from the ignition module board.
4. Remove the ignition module board from the
mounting bracket.
5. Reverse the procedure to install the
replacement ignition module board.
6. Check for proper operation.
SPARK IGNITER AND FLAME SENSE
WARNING: DISCONNECT (UNPLUG) ELECTRICAL
POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING YOU ARE
WORKING ON THE CIRCUIT.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE OVEN.
1. Remove the two gas burners as outlined
under Gas Burners.
2. Remove the screws securing the igniter and
flame sense to each burner. Remove the
assembly.
3. The spark gap is
1
/
8
" from the inside of the
spark rod to the inside to the ground rod. The
ground rod (the end of the spark) is
1
/
8
" above
the burner. If the gap is not correct or poor
sparking is occurring, then adjust accordingly.
4. Reverse the procedure to install the assembly
and check for proper operation.
Содержание SG4C ML-114876
Страница 2: ...2 VULCAN HART COMPANY 2002...
Страница 38: ...38 WIRING DIAGRAMS WIRING DIAGRAM SG4D SG6D OVENS 120 200 V 424372 Rev F...
Страница 39: ...39 WIRING DIAGRAM 734 COMPUTER CONTROL DUAL BURNER CONVECTION OVENS 120 200 V 426574 Rev C...
Страница 40: ...40 SCHEMATICS GAS CONVECTION OVEN SG4 WITH STD CONTROL 424373 1 REV C...
Страница 41: ...41 GAS CONVECTION OVEN SG4 WITH WATLOW 734 CONTROL 426575 1 REV C...