– 19 –
COOLING FAN
WARNING: DISCONNECT (UNPLUG) ELECTRICAL
POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING YOU ARE
WORKING ON THE CIRCUIT.
1. Remove the right side panel as outlined
under Covers and Panels.
2. Disconnect the lead wires to the fan motor by
removing the wire nuts.
3. Remove the screws securing the air deflector
to the fan, then loosen the tab screw holding
the fan to the component panel. Rotate the
tab so that the fan will clear. Remove the fan.
4. Reverse the procedure to install the
replacement fan and check for proper
operation.
Fan Installation Tips
• The fan must be installed so air is pulled from
the rear of the oven and blown into the control
area. The arrow on the fan body indicates
airflow direction and should be pointing toward
the controls.
• Ensure the fan is seated squarely against the
air tube and the oven bottom.
• The air deflector should be angled upward at
approximately 30 degrees to properly direct
the airflow.
Lamp Assembly
1. Remove the lens and bulb.
2. Remove the springs from the retaining tabs
(two places) on the socket.
3. Depress the retaining tabs and pull the socket
out from the oven, far enough to disconnect
the lead wires.
4. Remove the socket from the oven.
5. Attach the lead wires to the replacement
socket.
6. Insert the socket into the hole in the oven and
push until the socket is held in place by the
retaining tabs.
7. Install the light bulb and lens.
8. Ensure the case is connected to the green
ground wire.
8. Check for proper operation.
RETAINING TABS
SPRING
CROSS SECTIONAL VIEW
PL-56055
Содержание SG4C ML-114876
Страница 2: ...2 VULCAN HART COMPANY 2002...
Страница 38: ...38 WIRING DIAGRAMS WIRING DIAGRAM SG4D SG6D OVENS 120 200 V 424372 Rev F...
Страница 39: ...39 WIRING DIAGRAM 734 COMPUTER CONTROL DUAL BURNER CONVECTION OVENS 120 200 V 426574 Rev C...
Страница 40: ...40 SCHEMATICS GAS CONVECTION OVEN SG4 WITH STD CONTROL 424373 1 REV C...
Страница 41: ...41 GAS CONVECTION OVEN SG4 WITH WATLOW 734 CONTROL 426575 1 REV C...