VCW & VCD SERIES CHIP WARMER
F-38053 (08-14)
10
LOCKOUT / TAGOUT PROCEDURE
Always perform the LOCKOUT / TAGOUT
PROCEDURE of your facility before removing any sheet metal
panels or attempting to service this equipment.
The Lockout / Tagout Procedure is used to protect personnel working
on an electrical appliance. Before performing any type of
maintenance or service on an electrically operated appliance, follow
these steps:
1.
In electrical box, place unit’s circuit breaker into OFF position.
2.
Place a lock or other device on electrical box cover to prevent someone from
placing circuit breaker ON.
3.
Place a tag on electrical box cover to indicate that unit has been disconnected for
service and power should not be restored until tag is removed by maintenance
personnel.
4.
Disconnect unit power cord from electrical outlet.
5.
Place a tag on cord to indicate that unit has been disconnected for service and
power should not be restored until tag is removed by maintenance personnel