5.
While still holding knob in, light the pilot with a
flame. Continue to depress knob until pilot
remains lit (approximately 30 seconds), then
release knob.
6.
Depress and turn gas control valve knob to ON.
NOTE:
If gas supply is interrupted, repeat all steps.
DRAIN FRYER TANK
Oil may be hot when draining fryer tank.
1.
Turn thermostat off.
2.
Turn gas valve to "L" in PILOT to keep pilot lit.
Fig. 32
3.
Place container under drain valve (1, Fig. 33) to
drain shortening into.
Fig. 33
4.
Open the drain valve.
5.
Close drain valve when fryer tank is emptied.
MILLIVOLT CONTROLS TEST
1.
Verify proper gas (natural or propane) is present.
2.
Check for correct wiring and secure connections.
3.
Verify pilot flame is adjusted properly as outlined
in PILOT ADJUSTMENT.
NOTE:
If the pilot is not lit, light pilot. Refer to:
4.
Allow pilot to burn for 3 to 4 minutes to stabilize.
A.
If pilot remains lit, proceed to step 6.
B.
If pilot will not remain lit, proceed to step 5.
5.
Connect DC voltmeter to terminals TH-TP and
TH of combination valve. Relight pilot, hold gas
control valve knob in, and allow pilot to burn for
3 to 4 minutes to stabilize.
A.
lf voltage measures 450 millivolts or greater
and pilot will not stay lit, replace combination
valve.
B.
lf voltage is less than 450 millivolts, measure
voltage at terminals NO and C of high limit.
C.
If the voltage is less than 500 millivolts,
disconnect lead wire from terminal TH-TP
on combination valve and remeasure
voltage at the high limit.