– 7 –
6. Remove thermopile from pilot bracket.
7. Reverse procedure to install.
PILOT ORIFICE
WARNING:
SHUT OFF THE GAS BEFORE
SERVICING.
WARNING:
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
1. Remove pilot assembly from fryer as outlined
under thermopile.
2. Remove hex nut on the bottom of the pilot to
expose the orifice.
3. Replace orifice and reverse procedure to
assemble.
2. Remove the right hand burners as outlined
under Burners (optional).
3. Disconnect lead wires from combination valve
and mark for reconnecting.
4. Disconnect pilot tubing from combination
valve.
5. Disconnect combination valve union (Fig.1)
and pressure fitting (Fig. 2).
Fig.1 Fig. 2
6. Remove the combination valve from the fryer.
7. Reverse procedure to install.
COMBINATION VALVE
WARNING:
SHUT OFF THE GAS BEFORE
SERVICING.
WARNING:
ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1. Disconnect fryer from main gas supply.