GAS PRESSURE REGULATOR INSTALLATION 

Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. 
for propane gas. No further adjustment should be required. 

Install the regulator as close to the cheesemelter on the gas supply line as possible. 
Make sure that the arrow on the underside of the regulator is oriented in the direction of 
gas flow to the cheesemelter (Fig. 2) and the regulator is positioned with the vent plug 
and adjustment screw upright (Fig. 3). 

 

Fig. 2 

 

Fig. 3 

The supply pressure (upstream of the regulator) should be 7-9” W.C. for natural gas and 
11-12” W.C. for propane gas. At no time should the cheesemelter be connected to supply 
pressure greater than ½ psig (3.45 kPa) or 14” W.C. 

TESTING THE GAS SUPPLY SYSTEM 

When gas supply pressure exceeds ½ psig (3.45 kPa), the Cheesemelter and its 
individual shutoff valve must be disconnected from the gas supply piping system. 

When gas supply pressure is ½ psig (3.45 kPa) or less, the Cheesemelter should be 
isolated from the gas supply system by closing its individual manual shutoff valve. 

FLUE CONNECTIONS 

DO NOT

 obstruct flow of flue gases from the flue located on the rear of the Cheesemelter. 

It is recommended that the flue gases be ventilated to the outside of the building through 
a ventilation system installed by qualified personnel. 

Information on the construction and installation of ventilating hoods may be obtained from 
the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), 
available from The National Fire Protection Association, Batterymarch Park, Quincy, MA 
02269. 

 

- 6 - 

Содержание CMJ24 ML-135124

Страница 1: ...VCM48 ML 135127 VCM60 ML 135128 VCM72 ML 135129 www vulcanhart com MODELS MLS CMJ24 ML 135124 CMJ34 ML 135123 CMJ36 ML 135126 CMJ48 ML 135127 CMJ60 ML 135128 CMJ72 ML 135129 www wolfrange com ITW Food...

Страница 2: ...TANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMM...

Страница 3: ...located underneath the grease drip pan If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately UNPACKING Immediately after unpacking...

Страница 4: ...ards Committee Z223 400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1 Batterymarch Park Quincy MA 02169 7471 3 NFPA Standard 96 Vapor Removal from Cooking Equipment lat...

Страница 5: ...supply connections and any pipe joint compound must be resistant to the action of propane gases Location of the gas inlet is at the top right rear corner of the top panel Codes require that a gas shut...

Страница 6: ...ig 3 45 kPa or 14 W C TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds psig 3 45 kPa the Cheesemelter and its individual shutoff valve must be disconnected from the gas supply piping sys...

Страница 7: ...TIONS 1 Turn gas shutoff valve and burner valve to the OFF position and wait 5 minutes 2 Turn gas shutoff valve ON Light the pilot adjacent to the main burner Adjust the pilot valve screw until the pi...

Страница 8: ...ild soap and water applied with a damp cloth Rinse the surface with clean water and dry with a soft clean cloth Do not use abrasive cleaners or strong liquid cleaners on stainless steel surfaces as th...

Страница 9: ...side 1 Cheesemelter not level side to side 2 Cheesemelter burner improperly installed Uneven heat front to back Cheesemelter not level front to back Dried out products 1 Melting time too long or produ...

Отзывы: