background image

4

switch does not turn it on and off properly.

User service.

 Some user-serviceable components 

are described in the Troubleshooting section. We 

cannot guarantee repairs made or attempted by 

anyone other than authorized agencies.

Tool service must be performed only by 

qualified repair personnel.

 Service or 

maintenance performed by unqualified personnel 

could result in risk of injury. For example, internal 

wires may be misplaced or pinched, safety guard 

Guard against electric shock.

 Prevent body 

contact with grounded surfaces: pipes, radiators, 

ranges, and refrigerator enclosures. Before 

driving fasteners into walls, floors, or wherever 

“live” electrical wires may be encountered, try to 

ascertain whether there is a danger of shock.

Hearing protection.

 Wear ear protection when 

using the tool for extended periods. Prolonged 

exposure  to high intensity noise can cause 

hearing loss.

Safety glasses 

To prevent eye injuries, the tool 

operator and all persons in the work area must 

wear approved safety glasses conforming to ANSI 

Z87.1 specifications with permanently attached, 

rigid side shields.

Use clean, dry, regulated, compressed air 

at 70 

to 90 psi.

Do not connect tool to pressure which 

potentially exceeds 200 psi.
Air hose.

 Only use hose that is rated for a 

minimum working pressure of 150 psi or 150% 

of the maximum system pressure, whichever is 

greater.

Never use oxygen, carbon dioxide, combustible 

gases or any other bottled gas as a power 

source for this tool.

 Explosion and serious 

personal injury could result.

Couplings.

 Connect tool to the air supply hose 

with 1/4” NPT couplings that remove all pressure 

from the tool when the coupling is disconnnected.

Be aware of air hoses and their connections. 

Don’t trip over hoses. Make sure all connections 

are tight.

 

Disconnect tool from air supply hose before 

return springs may be improperly mounted.

When servicing tool, use only identical 

replacement parts.

  Follow instructions in 

the Maintenance section of this manual. Use 

of unauthorized parts or failure to follow 

Maintenance instructions may create a risk of 

injury. Certain cleaning agents such as gasoline, 

carbon tetrachloride, ammonia, etc. may damage 

plastic parts.

SAFETY RULES FOR AIR NAILERS

doing any disassembly, maintenance, loading 

fasteners, clearing a jammed fastener

, leaving 

the work area, moving the tool to another 

location, or handing the tool to another person.

Never use a tool that is leaking air, has missing 

or damaged parts, or requires repair.

 Before 

each use, make sure all screws and caps are 

securely tightened.

Check for damaged parts.

 Never use a tool if 

safety, trigger, or spring are inoperable, missing or 

damaged. Do not alter or remove safety, trigger, 

or springs. Make daily inspections for the free 

movement of trigger and safety mechanism.

Replacement parts

. When servicing, use 

only identical replacement parts and fasteners 

recommended by us.

Be sure the tool is disconnected from the air 

supply before loading the fasteners. 

Take 

care on re-connection: fasteners may be fired 

accidentally during connection. The fastener 

driving mechanism may cycle when the tool is 

connected to the air supply.

Assume the tool contains fasteners at all times.

 

Always keep it pointed away from yourself and 

others. No horseplay. Respect the tool as having 

lethal potential.

Do not load fasteners with trigger or safety 

depressed.

 The tool may unintentionally fire a 

fastener.

Do not depress the trigger unless the nosepiece 

is directed at the worksurface or when not 

driving fasteners. 

Never carry tool with finger on 

or touching the trigger mechanism: tool may fire 

an unwanted fastener.

Содержание 039-8438

Страница 1: ...Instruction Manual Manual de instrucciones ITEM NO 039 8438 ARTICULO No OCN45R 000 0000 v070823 Roofing Coil Nailer...

Страница 2: ...o material and workmanship for a period of ONE YEAR from date of purchase If defective the product will be repaired or replaced Call the Vulcan Power Tool customer service line at 1 800 482 0131 and a...

Страница 3: ...ctrical wires may be encountered try to ascertain whether there is a danger of shock Do not overreach Keep proper footing and balance at all times Do not reach over or across machines which are runnin...

Страница 4: ...ions Don t trip over hoses Make sure all connections are tight Disconnect tool from air supply hose before return springs may be improperly mounted When servicing tool use only identical replacement p...

Страница 5: ...rate Grip tool firmly to maintain control while allowing the tool to recoil away from the work surface as the fastener is driven If the safety is allowed to recontact the work surface before the trigg...

Страница 6: ...andard 7 8 1 3 4 x 11 ga 0 120 flat full round head max head diam 0 39 roofing coil nails in 120 nail 15 16 degree wire collated rolls Operating pressure 70 120 psi Air consumption 0 1 cubic foot per...

Страница 7: ...All compressed air contains moisture and other contaminates that are detrimental to internal components of the tool An airline filter will remove most of these contaminates and significantly prolong...

Страница 8: ...t to the desired position 7 Adjust the shingle guide by loosening the retaining screw and sliding the shingle guide to the desired position Tighten the retaining screw firmly The shingle guide can be...

Страница 9: ...ng the work area moving the tool to another location or handing the tool to another person Clean and inspect the tool daily Carefully check for proper operation of trigger and safety mechanism Do not...

Страница 10: ...d wear on the seals Check the filter of the compressor weekly Open drain cock to drain all water and contaminants out of the air tank Wipe the tool clean Blow the tool clean using high compressed air...

Страница 11: ...l screws tight Loose screws can cause personal injury or damage to the tool Check if there are worn and damaged parts If any please replace immediately PROBLEM CAUSE CORRECTION Trigger area leaks air...

Страница 12: ...maged Check or replace O ring lubricate Tool dry lacks lubrication Use air tool lubricant Skips fasteners intermittent feed Foreign matter between small piston cylinder Disassemble clean lubricate Sma...

Страница 13: ...g Tool runs slowly or has power loss Tool dry lacks lubrication Use air tool lubricant Spring in cylinder cap is damaged Replace spring Foreign matter between piston assembly and cylinder Disassemble...

Страница 14: ...Cylinder 22 O Ring 50 5 x 2 5 22A Restrictive plate 22B O Ring 70 4 x 3 5 23 Cylinder seal 24 Bumper 25 Protective piece No DESCRIPTION 26 Soft spacer 27 Body 28 O Ring 46 x 1 3 29 Restrictive washer...

Страница 15: ...Locking washer 60 Screw 61 Spring pin 62 Handle 63 Washer 64 Latch 65 Pin 66 Protector 67 Spring 68 Shaft 69 Pin 70 Stopped hook 71 Taper spring 72 Block plate 73 Spring washer No DESCRIPTION 74 Scre...

Страница 16: ...16 SCHEMATIC DRAWING...

Отзывы: