19
Adress
Function
Range
Resolution
Unit
0
Setpoint / PrcSet
0 - 10000
0.01
%
1
Min. Motor Speed
100 - Max.
0.01
RPM
2
Max. Motor Speed
Min. - 40000
0.01
RPM
3
Start I Out (Boost)
0 - ?
1
mA (RMS)
4
Start Time (Boost)
0 - ?
1
Sec.
8
Prc Holding Torque
0 - 1000
0.1
% of max
9
UpRampTime
15 - 300
1
Sec.
10
DownRampTime
15 - 300
1
Sec.
11
SwitchMode
0
(Auto)
1
8
kHz
2
10
kHz
12
DHX Type
0 - ?
1
-
13
Alternative Modbus ID
1 - 247
1
-
14
Alternative BaudRate
0
9600
bps
1
19200
bps
2
38400
bps
3
57600
bps
4
115200
bps
15
Alternative Parity
0
None
-
1
Odd
-
2
Even
-
16
Alternative Stop Bits
0
INVALID
-
1
1
-
2
2
-
17
Number of retries
-1 - 100
1
-
18
Modbus Timeout
0 - 240
1
Sec.
19
Pulley size (diameter)
0 - 1000
1
mm.
20
Rotor size (diameter)
0 - 10000
1
mm.
21
Pulses per rotation
0 - 10
1
-
22
K factor
0-10000
-
-
23
DigIn1 config
0
Disabled
-
1
Start/stop
-
2
AlarmReset
-
3
Rotation
direction
-
4
Test function
-
5
Ext. rotor guard
signal
-
6
Enable ext. rotor
guard
-